Powered by GoogleTranslate

Inspection Detail

Inspection: 119860138 - Ditty Container Inc.

Inspection Information - Office: Monrovia District Office

 

Inspection Nr: 119860138
Report ID: 0950644
Date Opened: 11/29/1993

Site Address:
Ditty Container Inc.
2226 N. Rosemead Blvd.
El Monte, CA 91733

Mailing Address:
2226 N. Rosemead Blvd., So. El Monte, CA 91733

Union Status: NonUnion

SIC:5085

NAICS: 0 


Inspection Type: Unprog Rel

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/27/1994

Emphasis:

Case Closed: 06/13/1995


Related Activity
Type Activity Nr Safety Health
Accident 361059959
Referral 901617530 Yes
Accident 361059496
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 4 6
Current Violations 1 4 5
Initial Penalty $10,000 $0 $0 $1,100 $0 $11,100
Current Penalty $5,000 $0 $0 $1,100 $0 $6,100
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 461 A 01/31/1994 03/05/1994 $400 $400 $0 -  
2. 01002 Other 3210 A 01/31/1994 03/05/1994 $300 $300 $0 -  
3. 01003 Other 5097 B01 01/31/1994 03/05/1994 $200 $200 $0 -  
4. 01004 Other 5420 A03 01/31/1994 03/05/1994 $200 $200 $0 -  
5. 02001 Serious 5418 C 01/31/1994 11/29/1993 $0 $5,000 $0 02/10/1994 J - ALJ Decision Citation has been deleted.
6. 03001 Serious 5418 E 12/24/1993 12/03/1993 $5,000 $5,000 $0 -  

Investigation Summary

Investigation Nr: 170733042
Event: 11/15/1993
Employee injured in gas explosion while sorting drums

At about 6:45 a.m. on November 16, a gas explosion occurred at Ditty Containers, Inc. The employer recycles used 55-gallon drums. Employee #1 had been working as a laborer with Ditty Containers for 5 months. On the day of the accident, Employee #1 was performing his usual work assignment of sorting the dirty drums from the clean ones. To accomplish this, Employee #1 had to check the inside of every drum with the use of a makeshift electric light probe. As he inserted the probe inside a drum that previously contained acetone, an explosion occurred. The employer was cited for violation of T8CCR5418(c) for allowing a source of ignition inside the drum. Other violations were observed and the employer was cited for those general violations.

Keywords: VAPOR, FLAMMABLE VAPORS, WORK RULES, DRUM, ACETONE, EXPLOSION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 119860138 Hospitalized injury Burn/Scald(Heat) Helpers, extractive occupations
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close