Powered by GoogleTranslate

Inspection Detail

Inspection: 119830578 - Teledyne Cast Products

Inspection Information - Office: Monrovia District Office

 

Inspection Nr: 119830578
Report ID: 0950644
Date Opened: 12/26/1995

Site Address:
Teledyne Cast Products
4200 W. Valley Blvd.
Pomona, CA 91766

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3369

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/25/1996

Emphasis:

Case Closed: 06/25/1996


Related Activity
Type Activity Nr Safety Health
Accident 362262701

Investigation Summary

Investigation Nr: 170731327
Event: 12/26/1995
Employee's ankle fractured when gas-fired oven explodes

At 9:30 a.m. on December 26, 1995, Employee #1, of Teledyne Casting Service, Pomona, CA, was installing a computer controlled thermostat (thermocouple) on a natural-gas-fired oven after test firing the oven that morning. He was at the control panel when the oven exploded. Employee #1 was treated at Pomona Valley Hospital for a fractured ankle. The employer reported the injury at 10:00 a.m. on December 26, 1995.

Keywords: FRACTURE, INSTALLING, OVEN, NATURAL GAS, EXPLOSION, STRUCK BY, ANKLE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 119830578 Hospitalized injury Fracture Electricians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.