Inspection Detail
Inspection: 119826303 - Temperform Usa
Inspection Information - Office: Monrovia District Office
Site Address:
Temperform Usa
14425 Macaw Street
La Mirada, CA 90638
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3398
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/18/2001
Emphasis:
Case Closed: 08/28/2001
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 362555930 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 4 | 4 | ||||
Current Violations | 4 | 4 | ||||
Initial Penalty | $0 | $0 | $0 | $3,100 | $0 | $3,100 |
Current Penalty | $0 | $0 | $0 | $3,100 | $0 | $3,100 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 3661 C | 05/18/2001 | 06/14/2001 | $275 | $275 | $0 | - | ||
2. | 01002 | Other | 3308 | 05/18/2001 | 06/14/2001 | $550 | $550 | $0 | - | ||
3. | 01003 | Other | 5194 F04 | 05/18/2001 | 06/14/2001 | $275 | $275 | $0 | - | ||
4. | 01004 | Other | 3221 D01 | 05/18/2001 | 06/14/2001 | $2,000 | $2,000 | $0 | - |
Investigation Summary
At approximately 8.00 a.m. on November 22, 2000, five employees were exposed to smoke inhalation from a fire, which erupted inside a building used for heat treatment of aluminum metal parts. Hot exhaust gases leaked from the exhaust ductwork near the ceiling, and caused a fire, which quickly spread to the building walls. The five employees who suffered smoke inhalation were engaged in the fire fighting activity. However, upon investigation it was learned that they were not trained to perform this task. The employees were taken to a nearby industrial clinic, where they were hospitalized and treated for asphyxia.
Keywords: EXHAUST SYSTEM, ASPHYXIATED, WALL, CEILING, FIRE EXTINGUISHER, FIRE, SMOKE, FIRE BRIGADE, SMOKE INHALATION, WATER
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 119826303 | Hospitalized injury | Asphyxia | Heat treating equipment operators | ||
2 | 119826303 | Hospitalized injury | Asphyxia | Heat treating equipment operators | ||
3 | 119826303 | Hospitalized injury | Asphyxia | Heat treating equipment operators | ||
4 | 119826303 | Hospitalized injury | Asphyxia | Heat treating equipment operators | ||
5 | 119826303 | Hospitalized injury | Asphyxia | Heat treating equipment operators |