Powered by GoogleTranslate

Inspection Detail

Inspection: 119820827 - Cascade Pump

Inspection Information - Office: Monrovia District Office

 

Inspection Nr: 119820827
Report ID: 0950644
Date Opened: 12/17/2001

Site Address:
Cascade Pump
10107 S Norwalk Blvd
Santa Fe Springs, CA 90670

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3561

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/11/2002

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 05/20/2002


Related Activity
Type Activity Nr Safety Health
Accident 362558041
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 6 10
Current Violations 1 7 8
Initial Penalty $25,425 $0 $0 $1,915 $0 $27,340
Current Penalty $1,800 $0 $0 $1,200 $0 $3,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 14308 A 01/11/2002 02/11/2002 $0 $350 $0 I - Informal Settlement Citation has been deleted.
2. 01002 Other 3203 A 01/11/2002 02/11/2002 $100 $260 $0 I - Informal Settlement  
3. 01003 Other 23400017 A 01/11/2002 02/11/2002 $0 $260 $0 I - Informal Settlement  
4. 01004 Other 25000008 A 01/11/2002 02/11/2002 $0 $260 $0 I - Informal Settlement  
5. 01005 Other 25000010 A 01/11/2002 02/11/2002 $100 $260 $0 I - Informal Settlement  
6. 01006 Other 4309 D 01/11/2002 02/11/2002 $200 $525 $0 I - Informal Settlement  
7. 02001 Other 5044 A 01/11/2002 01/25/2002 $400 $3,150 $0 I - Informal Settlement  
8. 03001 Other 4002 A 01/11/2002 01/25/2002 $400 $3,150 $0 I - Informal Settlement  
9. 04001 Serious 5021 A 01/11/2002 01/25/2002 $0 $4,725 $0 I - Informal Settlement Citation has been deleted.
10. 05001 Serious 3384 B 01/11/2002 01/25/2002 $1,800 $14,400 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 201794963
Event: 12/13/2001
Employee Amputates Thumb While Using Drill Press

At approximately 12:01 p.m. on December 13, 2001, Employee #1 was operating a Cincinnati Bickford radial drill press, Serial Number 6NE25, drilling 0.875-inch holes in two large steel flanges. The flanges were placed one on top of the other and on top of both was a template flange. The employee used a bushing in the template so the template holes would not be damaged by the drilling. The employee raised the drill, removed the bushing, and was placing it in the next hole when his work glove on his right hand became entangled in the rotating drill bit, turned him around, and threw him to the ground. A coworker helped him to a nearby table and stayed with him until the paramedics arrived. Employee #1 was transported to USC Medical Center where he was treated for total amputation of the right thumb and for bruises on his right arm and back.

Keywords: AMPUTATED, GLOVE, THUMB, DRILL PRESS, ARM, ENTANGLED, CONTUSION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 119820827 Non Hospitalized injury Amputation Drilling and boring machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close