Inspection Detail
Inspection: 119812436 - Sacramento, County, Street Cleaning Dept.
Inspection Information - Office: Sacramento District Office
Site Address:
Sacramento, County, Street Cleaning Dept.
1628 - 50th St.
Sacramento, CA 95819
Mailing Address:
921 - 10th St., #400, Sacramento, CA 95814
Union Status: Union
SIC:9621
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: LocalGovt
Safety/Health: Safety
Close Conference: 04/19/1993
Emphasis:
Case Closed: 05/26/1993
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 361329105 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 2 | ||||
Current Violations | 2 | 2 | ||||
Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 5162 E | 04/16/1993 | 05/17/1993 | $0 | $0 | $0 | - | ||
2. | 01002 | Other | 3328 G | 04/16/1993 | 04/15/1993 | $0 | $0 | $0 | - |
Investigation Summary
Employee #1, the operator of a trash collection vehicle, worked in tandem with the operator of a front end loader as a two-man street cleaning team. A load of debris had been taken to the city landfill. Equipment W-11-B-7039 to be at rest for about 1 hour. Upon returning, about 2 to 3 streets had been worked when the operator of 7039 noted fluid spots on the street surface and a rapid rise of the temperature gauge, and parked at the rear of the collector vehicle. Employee #1 heard a hissing sound and proceeded to the rear of 7039. He was within 3 to 5 feet of the vehicle when it blew its coolant hose and sprayed him with water, ethylene glycol, and steam/vapor. A coworker quickly administered first aid, preventing the 2nd-degree burns the employee sustained on 17 percent of his body from becoming 3rd-degree burns. The adapter connecting the exhaust manifold to the engine split just above the weld, causing the hot exhaust gases to be focused on the 2 to 5 in. diameter non-reinforced coolant hose. Steam/glycol vapors were generated and the hose burst with a moderate overpressure. Steam/vapors and liquid were estimated to have spread out about 30 to 35 feet, according to witnesses.
Keywords: BURN, EXHAUST SYSTEM, VAPOR, ETHYLENE GLYCOL, EQUIPMENT FAILURE, GAS, HOSE, STEAM, HIGH PRESSURE, WATER
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 119812436 | Hospitalized injury | Burn/Scald(Heat) | Supervisors, motor vehicle operators |