Inspection Detail
Inspection: 119805620 - Modesto Tallow Co
Inspection Information - Office: Modesto District Office
Site Address:
Modesto Tallow Co
925 Crows Landing Rd
Modesto, CA 95351
Mailing Address:
P O Box 1036, Modesto, CA 95353
Union Status: NonUnion
SIC:2077
NAICS: 0
Inspection Type: Complaint
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/25/1993
Emphasis:
Case Closed: 01/05/2011
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361374689 | ||
| Complaint | 76054527 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $1,590 | $0 | $0 | $0 | $0 | $1,590 |
| Current Penalty | $1,590 | $0 | $0 | $0 | $0 | $1,590 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 3329 D | 03/25/1993 | 04/10/1993 | $1,590 | $1,590 | $0 | - |
Investigation Summary
At approximately 9:30 p.m. on November 24, 1993, Employee #1 was operating a feather cooker. Having completed primary timed cooking, he turned off the steam to the jacket and opened the vent line to draw steam from the cooker. Normally he would then go up to the next level and open the pressure hatch on top of the unit, but he was interrupted. He then mistakenly tried to open an adjacent cooker that was pressurized. There are no means such as gauges or identifying numbers to avoid confusion and mistakes. He attempted to open the hatch, utilizing a pry bar and the help of Employee #2. When the latch dog released, the hatch was forced up violently, stripping the threads of the axle nut. The hatch was blown completely off, erupting steam and feathers that burned both employees.
Keywords: BURN, WORK RULES, COOKER, RUPTURE, STEAM, HIGH PRESSURE, PRESSURE RELEASE, HIGH TEMPERATURE, INATTENTION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 119805620 | Non Hospitalized injury | Burn/Scald(Heat) | Miscellaneous plant and system operators | ||
| 2 | 119805620 | Non Hospitalized injury | Burn/Scald(Heat) | Miscellaneous plant and system operators |
Translate