Inspection Detail
Inspection: 119793552 - Sup Herb Farms
Inspection Information - Office: Modesto District Office
Site Address:
Sup Herb Farms
300 Diana Drive
Turlock, CA 95380
Mailing Address:
P.O.Box 610, Turlock, CA 95381
Union Status: NonUnion
SIC:2099
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/03/1993
Emphasis:
Case Closed: 11/08/1993
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361370760 |
Investigation Summary
On the morning of September 28, 1993, Employee #1, an experienced mechanic, was adjusting a slipping v-belt drive on an oscillating conveyor. Employee #1 locked out the motor controller and tagged it, retaining the key in his possession. He removed the guard and adjusted the belt. He then removed the lock and reset the disconnect. He returned to the conveyor and squatted near the running drive to watch for possible belt slippage. Employee #1 lost his balance and inadvertently reached to steady himself, catching his thumb in an in-running v-belt nip point.
Keywords: MECHANIC, CAUGHT BY, THUMB, V-BELT, NIP POINT, LOST BALANCE, UNGUARDED
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 119793552 | Hospitalized injury | Amputation | Specified mechanics and repairers |