Inspection Detail
Inspection: 119789147 - Plastic Dress-Up Company
Inspection Information - Office: Monrovia District Office
Site Address:
Plastic Dress-Up Company
11077 East Rush Street
South El Monte, CA 91733
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3089
NAICS: 326199/All Other Plastics Product Manufacturing
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/05/2004
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 05/05/2004
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362595076 |
Investigation Summary
At approximately 10:30 p.m. on March 31, 2004, an employee, a mold maker, had just finished welding a shaft to a drill pit to increase the drill pit's length and he was wearing net gloves, Interstate Gloves Inc., Part Number H20021. He then moved to the lathe, Cadillac, PDU Number: 130-9, Model Number 1749, Serial Number: 059138, to turn the new tool to the required diameter. He forgot to take off the gloves. As soon as he turned on the lathe his glove became entangled with the drill pit. The employee sustained a fracture of his right fifth finger. He was transported to U S Health Works in the City of Industry, and then transferred to Queen of the Valley Hospital in West Covina, where he was hospitalized and treated for fracture.
Keywords: FRACTURE, LATHE, FINGER, GLOVE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 119789147 | Hospitalized injury | Fracture | Molding and casting machine operators |
Translate