Inspection Detail
Inspection: 119787943 - Hanley Heating & Air Conditioning
Inspection Information - Office: Long Beach District Office
Site Address:
Hanley Heating & Air Conditioning
3470 Randolph St.
Huntington Park, CA 90255
Mailing Address:
P.O. Box 18361, Encino, CA 91416
Union Status: NonUnion
SIC:1711
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/14/1997
Emphasis:
Case Closed: 03/19/2003
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362532558 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 3 | 5 | |||
| Current Violations | 2 | 1 | 3 | |||
| Initial Penalty | $2,500 | $0 | $0 | $2,000 | $0 | $4,500 |
| Current Penalty | $1,250 | $0 | $0 | $125 | $0 | $1,375 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 1509 A | 03/11/1997 | 04/09/1997 | $125 | $750 | $0 | 05/08/1997 | W - Empr Withdrew | |
| 2. | 01002 | Other | 1509 B | 03/11/1997 | 04/09/1997 | $625 | $625 | $0 | 05/08/1997 | W - Empr Withdrew | Citation has been deleted. |
| 3. | 01003 | Other | 1509 D | 03/11/1997 | 04/09/1997 | $625 | $625 | $0 | 05/08/1997 | W - Empr Withdrew | Citation has been deleted. |
| 4. | 02001 | Serious | 1670 A | 03/11/1997 | 03/14/1997 | $625 | $1,250 | $0 | 05/08/1997 | W - Empr Withdrew | |
| 5. | 03001 | Serious | 23400017 A | 03/14/1997 | 03/19/1997 | $625 | $1,250 | $0 | 05/08/1997 | W - Empr Withdrew |
Investigation Summary
Employee #1, a foreman HVAC installer with Hanley Heating and Air, was climbing a ladder to reach an elevated location when he fell 15 ft to the floor. He was transported to the hospital, where he remained for over 24 hours. Although the cause of the accident was not determined, the employer was cited for lack of fall protection during the installation of overhead duct work. The employer was also cited for unguarded energized parts because of the 220 volt uninsulated wires that were in close proximity to Employee #1 when he fell.
Keywords: INSTALLING, WORK RULES, LADDER, CONSTRUCTION, UNGUARDED LIVE PARTS, FALL, FALL PROTECTION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 119787943 | Hospitalized injury | Concussion | Occupation not reported |