Inspection: 119785491 - Fibernetics (Bac Acquisition)

Inspection Information - Office: Long Beach District Office

 

Inspection Nr: 119785491
Report ID: 0950642
Date Opened: 08/19/1996

Site Address:
Fibernetics (Bac Acquisition)
1418 S. Alameda St.
Compton, CA 90220

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3714

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/19/1996

Emphasis:

Case Closed: 07/19/1997


Related Activity
Type Activity Nr Safety Health
Accident 362532251
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 2 7
Current Violations 4 2 6
Initial Penalty $13,660 $0 $0 $335 $0 $13,995
Current Penalty $6,965 $0 $0 $185 $0 $7,150
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 4845 B 12/19/1996 01/21/1997 $185 $0 $0 A - Amendment  
2. 01002 Other 3314 F 12/19/1996 01/21/1997 $0 $335 $0 A - Amendment  
3. 02001 Serious 23400001 12/19/1996 01/21/1997 $935 $2,475 $0 A - Amendment  
4. 03001 Serious 3314 A 12/19/1996 01/21/1997 $5,000 $5,000 $0 -  
5. 04001 Serious 4050 A 12/19/1996 01/21/1997 $935 $1,855 $0 A - Amendment  
6. 05001 Serious 4075 A 12/19/1996 01/21/1997 $95 $2,475 $0 A - Amendment  
7. 06001 Serious 4851 E 12/19/1996 01/21/1997 $1,855 $1,855 $0 A - Amendment Citation has been deleted.

Investigation Summary

Investigation Nr: 170882245
Event: 08/12/1996
Employee injured when die platen falls on him

Employee #1, of Fibernetics in Compton, CA, was told to finish setting up a 6 ft by 10 ft vacuum forming machine. He entered the area under the raised platen to hook up the hose at the rear of the machine to complete the set up. Employee #1 was at ground level, working on the vacuum hose, when the threaded portion of a 6 in. air cylinder shaft broke. This caused the 1,300 lb platen to drop and cock to one side. A short time later the other air cylinder, located directly across from the broken one, snapped its shaft at the threaded portion. These two air cylinders raise and lower the die platen; with both shafts broken, the platen fell, striking Employee #1. He suffered two fractured ribs and was admitted to Martin Luther King Hospital, where x-rays were taken and he was admitted for treatment. No special instructions had been given to Employee #1 regarding lockout or tagout procedures, and no precautionary measures were taken, such as blocking out the platen through mechanical means.

Keywords: DIE, FRACTURE, MOLDING MACHINE, WORK RULES, EQUIPMENT FAILURE, RIB, STRUCK BY, FALLING OBJECT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 119785491 Hospitalized injury Fracture Misc. metal,plastic,stone&glass-working mach. op's
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.