Powered by GoogleTranslate

Inspection Detail

Inspection: 119775823 - K.C.Photo Engraving

Inspection Information - Office: Monrovia District Office

 

Inspection Nr: 119775823
Report ID: 0950644
Date Opened: 09/22/1995

Site Address:
K.C.Photo Engraving
2666 E. Nena St.
Pasadena, CA 91107

Mailing Address:
, , 00000

Union Status: Union

SIC:2796

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 12/21/1995

Emphasis:

Case Closed: 04/03/1996


Related Activity
Type Activity Nr Safety Health
Accident 362262289
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3 6
Current Violations 1 5 6
Initial Penalty $2,745 $0 $0 $685 $0 $3,430
Current Penalty $1,375 $0 $0 $685 $0 $2,060
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A 12/22/1995 01/26/1996 $275 $275 $0 I - Informal Settlement  
2. 01002 Other 5194 F04 12/22/1995 01/26/1996 $0 $135 $0 I - Informal Settlement  
3. 01003 Other 3203 B01 12/22/1995 01/26/1996 $0 $275 $0 I - Informal Settlement  
4. 02001 Other 4475 B 12/22/1995 01/26/1996 $135 $685 $0 I - Informal Settlement  
5. 03001 Other 23400017 A 12/22/1995 01/26/1996 $275 $685 $0 I - Informal Settlement  
6. 04001 Serious 5416 C 12/22/1995 01/26/1996 $1,375 $1,375 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 170903140
Event: 09/13/1995
Employee's arm burned in solvent vapor flash fire

At approximately 7:00 a.m. on September 13, 1995, Employee #1 was working on a solvent recovery system to recycle solvent generated from a Flexographic printing process. As the spent solvent was poured into the system, sludge started to rise and a cloud of white smoke began to form. In closing the machine, the lid hit against the metal surface and generated a spark that ignited the solvent vapors. Employee #1's sustained second-degree burns to his upper right arm and was taken to St. Luke's Hospital, where he was treated and released the same day. Subsequent investigation determined that no tests had been conducted, nor a continuous monitor used, to ensure that the LFL (Lowest Flammability Level) concentration of flammable gases was not exceeded. The employer was cited for a serious violation of T8CCR 5416(c) and regulatory violation of T8CCR 3203(b)(1).

Keywords: BURN, VAPOR, FLAMMABLE VAPORS, UNSECURED, FIRE, SPARK, ARM, CHEMICAL VAPOR, CHEMICAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 119775823 Non Hospitalized injury Burn/Scald(Heat) Managers and administrators, n.e.c
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close