Inspection Detail
Inspection: 119775070 - Xar Industries
Inspection Information - Office: Monrovia District Office
Site Address:
Xar Industries
151 Puente Avenue
Industry, CA 91746
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3728
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 11/27/1995
Emphasis:
Case Closed: 09/13/2010
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361365844 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 4 | 1 | 5 | |||
| Current Violations | 1 | 4 | 5 | |||
| Initial Penalty | $8,585 | $0 | $0 | $1,750 | $0 | $10,335 |
| Current Penalty | $4,375 | $0 | $0 | $2,025 | $0 | $6,400 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3203 C | 11/27/1995 | 12/07/1995 | $900 | $1,750 | $0 | 12/18/1995 | J - ALJ Decision | |
| 2. | 02001 | Other | 23400023 | 11/27/1995 | 12/07/1995 | $375 | $840 | $0 | 12/18/1995 | J - ALJ Decision | |
| 3. | 03001 | Other | 25220002 A | 11/27/1995 | 12/08/1995 | $375 | $1,685 | $0 | 12/18/1995 | J - ALJ Decision | |
| 4. | 04001 | Serious | 5416 A | 11/27/1995 | 12/07/1995 | $4,375 | $4,375 | $0 | 12/18/1995 | J - ALJ Decision | |
| 5. | 05001 | Other | 3308 | 11/27/1995 | 12/07/1995 | $375 | $1,685 | $0 | 12/18/1995 | J - ALJ Decision |
Investigation Summary
Employee #1 was performing a test on a valve under high temperatures. He heated a container with approximately 75 gallons of petroleum naphtha with an MSDS flash point of 104 degrees Fahrenheit and an autoignition point of 450 degrees. The laboratory analysis of this sample's flash point was 110 degrees. Employee #1 heated the container with 220 volt heating strips with a surface temperature of 725 degrees. The naphtha needed to be heated to 200 degrees to test the valve. The naphtha was heated for two hours, but it only got to 170 degrees. Employee #1 attempted to increase the temperature by tightening the wire straps that held the heat strips on the tank. The tank flashed and caught fire and the lid blew off the tank. Employee #1 suffered 1st- and 2nd- degree burns on his face.
Keywords: BURN, FIRE, NAPHTHA, EXPLOSION, VALVE, FACE, HIGH TEMPERATURE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 119775070 | Hospitalized injury | Burn/Scald(Heat) | Technicians, n.e.c. |
Translate