Powered by GoogleTranslate

Inspection Detail

Inspection: 119750388 - Nor Cap Sales & Service

Inspection Information - Office: Sacramento District Office

 

Inspection Nr: 119750388
Report ID: 0950621
Date Opened: 10/28/1992

Site Address:
Nor Cap Sales & Service
Hwy. 50 And Hazel Ave.
Folsom, CA 95630

Mailing Address:
P. O. Box 520, Galt, CA 95632

Union Status: NonUnion

SIC:7699

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/21/1992

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 12/21/1992


Related Activity
Type Activity Nr Safety Health
Accident 361328255
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $0 $0 $0 $150 $0 $150
Current Penalty $0 $0 $0 $150 $0 $150
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 5432 A 02/10/1993 10/22/1992 $150 $150 $0 -  

Investigation Summary

Investigation Nr: 170716120
Event: 10/22/1992
Employee burned in flash fire

Employee #1 had completed insulating a storage tank, which measured approximately 8 ft in diameter by 20 ft long, with a polyester resin. He was standing on a plank about 30 in. above the lower tank surface smoothing out the resin strips applied to the fill port. Confined space procedure was being followed with two coworkers outside the tank, and Employee #1 was wearing a full face respirator connected to a powered air supply. An explosion-proof lamp was on the lower tank surface. A plastic 5-gal bucket contained 1 to 2 pints of acetone used to clean the resin applicator. The resin dropped onto the respirator face piece and hose as well as his coveralls. Employee #1 dropped the bucket, and because the acetone hit the surface of the lamp, a flash fire developed. The fire burned his coveralls and respirator. Employee #1 removed the respirator and inhaled the vapors and smoke. He was flown from the "H" area of Aerojet to University of California Davis 7 by Life Flite.

Keywords: BURN, CLOTHING, CONFINED SPACE, FLAMMABLE LIQUID, FIRE, LIGHTING FIXTURE, ACETONE, SCBA, SMOKE INHALATION, RESPIRATOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 119750388 Hospitalized injury Burn/Scald(Heat) Insulation Workers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.