Inspection Detail
Inspection: 119745669 - Splish Splash Auto Body
Inspection Information - Office: Foster City District Office
Site Address:
Splish Splash Auto Body
895 Hurlingame Avenue
Redwood City, CA 94063
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:7532
NAICS: 0
Inspection Type: Complaint
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/27/1994
Emphasis:
Case Closed: 05/11/2007
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Complaint | 76123264 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 4 | 5 | |||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $3,000 | $0 | $0 | $900 | $0 | $3,900 |
| Current Penalty | $3,000 | $0 | $0 | $0 | $0 | $3,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 342 A | 04/29/1994 | 03/17/1994 | $0 | $300 | $0 | 05/23/1994 | D - Govt Dismissed | Citation has been deleted. |
| 2. | 01002 | Other | 3203 A | 04/29/1994 | 06/01/1994 | $0 | $150 | $0 | 05/23/1994 | D - Govt Dismissed | Citation has been deleted. |
| 3. | 01003 | Other | 3203 A07 C | 04/29/1994 | 05/17/1994 | $0 | $225 | $0 | 05/23/1994 | D - Govt Dismissed | Citation has been deleted. |
| 4. | 01004 | Other | 3241 A | 04/29/1994 | 06/01/1994 | $0 | $225 | $0 | 05/23/1994 | D - Govt Dismissed | Citation has been deleted. |
| 5. | 02001 | Serious | 3270 B | 04/29/1994 | 05/17/1994 | $3,000 | $3,000 | $0 | - |
Investigation Summary
Employee #1, a mechanic at Splish Splash Auto Body, was trying to retrieve an oil pan from a crawl space that was used as a storage area for miscellaneous auto parts. No safe platform was provided to stand on, nor was a fixed ladder provided for access. Employee #1 fell between the ceiling joists and through the gypboard ceiling approximately 8 feet 6 inches to the concrete floor. He suffered a spinal injury and underwent surgery.
Keywords: SPINE, WORK RULES, MECHANIC, FALL, FALL PROTECTION, STORAGE AREA, CRAWL SPACE, UNSTABLE POSITION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 119745669 | Hospitalized injury | Fracture | Automobile mechanics |