Inspection Detail
Inspection: 119738417 - Rios Grading Inc.
Inspection Information - Office: Foster City District Office
Site Address:
Rios Grading Inc.
7800 El Camino Real
Colma, CA 94015
Mailing Address:
4415 Cowell Rd. Suite1040, Concord, CA 94521
Union Status: Union
SIC:1611
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/12/1994
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 12/16/1994
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 361346141 |
Investigation Summary
Employee #1, of Rios Grading and Excavating, was sitting inside a truck's cab. The dump box's ram failed, and the cylinder collapsed. The shock of the impact of the bed on the frame caused Employee #1 to hit his head on top of the truck's cab. He suffered a head injury, which did not require that he be hospitalized.
Keywords: HEAD, STRUCK AGAINST, CONSTRUCTION, EQUIPMENT FAILURE, HYDRAULIC CYLINDER, TRUCK, DUMP TRUCK, DUMP TRUCK BED
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 119738417 | Non Hospitalized injury | Asphyxia | Occupation not reported |