Inspection Detail
Inspection: 119733996 - Pioneer Concrete
Inspection Information - Office: American Canyon District Office
Site Address:
Pioneer Concrete
1240 Century Ct.
Santa Rosa, CA 95403
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3272
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/15/1994
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 08/03/2007
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361379019 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | 2 | |||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $3,500 | $0 | $0 | $85 | $0 | $3,585 |
| Current Penalty | $1,300 | $0 | $0 | $0 | $0 | $1,300 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 467 B | 06/15/1994 | 06/15/1994 | $0 | $85 | $0 | 06/23/1994 | F - Formal Settlement | Citation has been deleted. |
| 2. | 02001 | Serious | 467 A | 06/22/1994 | 07/15/1994 | $1,300 | $3,500 | $0 | 06/23/1994 | F - Formal Settlement |
Investigation Summary
Employee #1 was standing in front of a water tank, pressurizing it in order to locate a leak. The tank, which had no pressure relief valve, was rated for 50 psi. When 120 psi was introduced it exploded, and the tank end fractured Employee #1's leg.
Keywords: LEAK, FRACTURE, REPAIR, WORK RULES, EXPLOSION, HIGH PRESSURE, VALVE, WATER TANK, INATTENTION, LEG
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 119733996 | Hospitalized injury | Fracture | Machinery maintenance occupations |