Powered by GoogleTranslate

Inspection Detail

Inspection: 119706109 - Purity Systems, Inc.

Inspection Information - Office: Oakland District Office

 

Inspection Nr: 119706109
Report ID: 0950614
Date Opened: 03/20/1995

Site Address:
Purity Systems, Inc.
1933 O'Toole Ave
San Jose, CA 95131

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:7389

NAICS: 0 


Inspection Type: Complaint

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 06/15/1995

Emphasis:

Case Closed: 09/06/1995


Related Activity
Type Activity Nr Safety Health
Accident 362138687
Complaint 78025293 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $0 $0 $0 $350 $0 $350
Current Penalty $0 $0 $0 $350 $0 $350
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A 06/30/1995 07/30/1995 $175 $175 $0 -  
2. 01002 Other 5194 E01 06/30/1995 07/30/1995 $175 $175 $0 -  

Investigation Summary

Investigation Nr: 170376586
Event: 02/02/1995
Employee suffers sore throat after inhaling chlorine gas

At approximately 2:00 p.m. on February 2, 1995, Employee #1, a pipe inspector for Purity Systems, was working in Building R of Quad l at Lam Research. On the second floor of the building, machines are tested before they are sent to semiconductor manufacturers. Gases are used in the semiconductor fabrication process and the gas supply pipes come from the sub-fab on the first floor of Building R. At the time of the accident, some of these pipes were in use and others were being installed. Employee #1 was alone in the sub-fab testing an inactive pipe when he smelled chlorine gas and immediately left the building. Approximately 20 minutes later, he felt a burning sensation in his throat. He was sent to Valley Medical Center, San Jose, CA, examined, and released the same day.

Keywords: RESPIRATORY, LUNG, INHALATION, GAS, CHLORINE, CHEMICAL BURN, CHEMICAL VAPOR, OVEREXPOSURE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 119706109 Non Hospitalized injury Burn(Chemical) Mechanical engineering technicians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close