Powered by GoogleTranslate

Inspection Detail

Inspection: 119696029 - Nummi-New United Motor Manufacturing, Inc

Inspection Information - Office: Oakland District Office

 

Inspection Nr: 119696029
Report ID: 0950614
Date Opened: 05/13/1994

Site Address:
Nummi-New United Motor Manufacturing, Inc
45500 Fremont Blvd
Fremont, CA 94538

Mailing Address:
, , 00000

Union Status: Union

SIC:3711

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/27/1994

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 05/15/1997


Related Activity
Type Activity Nr Safety Health
Accident 362119190
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 4
Current Violations 3 1 4
Initial Penalty $12,500 $0 $0 $1,500 $0 $14,000
Current Penalty $5,250 $0 $0 $750 $0 $6,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A 2 06/28/1994 07/16/1994 $750 $1,500 $0 A - Amendment  
2. 02001 Serious 3203 A 7 06/28/1994 07/06/1994 $1,500 $3,750 $0 A - Amendment  
3. 03001 Serious 3314 A 06/28/1994 07/06/1994 $3,750 $3,750 $0 -  
4. 04001 Serious 3328 E 06/28/1994 07/06/1994 $0 $5,000 $0 A - Amendment  

Investigation Summary

Investigation Nr: 170374797
Event: 03/14/1994
Employee's left thumb caught in spot welding machine

Employee #1 reached into the work area of a semi-automated multiple point, spot welding machine to reposition a mis-set piece, and a clamp closed on her hand. The employee sustained multiple fractures to her left thumb. Her hand was caught under a parts clamp that moved unexpectedly after an emergency stop default was initiated by a photoelectric presence sensing device that was interrupted. The compressed air-powered actuating ram, which closes the clamp, remains pressurized when the emergency stop is activated. The clamp became stuck against the mis-set part at the start of the machine cycle causing a process default to stop the welder. The pneumatic ram stores pressure (energy) that enables movement even with the emergency stop default. The machine's ID # is FWS-0606.

Keywords: FRACTURE, SPOT WELDING, STUCK, COMPRESSED AIR, THUMB, EMERGENCY STOP, CRUSHED, MECH MALFUNCTION, MACHINE--MISC

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 119696029 Hospitalized injury Fracture Misc. metal,plastic,stone&glass-working mach. op's
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.