Powered by GoogleTranslate

Inspection Detail

Inspection: 119690337 - Shelton Roofing

Inspection Information - Office: Fremont District Office

 

Inspection Nr: 119690337
Report ID: 0950612
Date Opened: 07/17/2001

Site Address:
Shelton Roofing
1091 Shoreline Blvd
Mountain View, CA 94043

Mailing Address:
1988 Leghorn Street, Mountain View, CA 94043

Union Status: Union

SIC:1761

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/14/2001

Emphasis: S:Construction (Cship)

Case Closed: 02/05/2002


Related Activity
Type Activity Nr Safety Health
Accident 102341476
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $0 $0 $0 $1,275 $0 $1,275
Current Penalty $0 $0 $0 $1,275 $0 $1,275
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 14305 C 12/11/2001 12/28/2001 $300 $300 $0 -  
2. 01002 Other 5194 E01 12/11/2001 12/28/2001 $450 $450 $0 -  
3. 01003 Other 1509 A 12/11/2001 12/28/2001 $300 $300 $0 -  
4. 01004 Other 1510 C 12/11/2001 12/28/2001 $225 $225 $0 -  

Investigation Summary

Investigation Nr: 202313011
Event: 06/27/2001
Employee burned by hot asphalt when kettle gasket fails

On June 27, 2001, Employee #1 and two coworkers were removing, cleaning, preparing, and sealing with hot asphalt the skylights at a shopping center. Employee #1 was on the ground attending the recirculation valve on a kettle of hot asphalt and a 20 ft long pipe that was to deliver the hot asphalt to the roof. He was also assigned to keep pedestrians away from the setup. After the kettle was ignited and the thermostat set between 450 and 500 degrees F, a coworker on the roof pulled on a rope attached to the recirculation valve lever to start the hot asphalt pumping through the pipe. Employee #1 was standing approximately 24 in. to 36 in. from the kettle when the gasket failed on the recirculation valve and he was sprayed by hot asphalt. He sustained burns, for which he was hospitalized.

Keywords: BURN, ROOF, GASKET, CONSTRUCTION, EQUIPMENT FAILURE, HOT ASPHALT, VALVE, ACCIDENTAL DISCHARGE, HIGH TEMPERATURE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 119690337 Hospitalized injury Burn(Chemical) Construction laborers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close