Inspection: 119689651 - Acme & Sons Sanitation

Inspection Information - Office: Ca Fremont District Office

 

Inspection Nr: 119689651
Report ID: 0950612
Date Opened: 09/06/2000

Site Address:
Acme & Sons Sanitation
3408 Hillcap Ave
San Jose, CA 95136

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2842

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/17/2001

Emphasis:

Case Closed: 10/30/2001


Related Activity
Type Activity Nr Safety Health
Accident 101798262
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 12 15
Current Violations 3 12 15
Initial Penalty $35,125 $0 $0 $3,305 $0 $38,430
Current Penalty $35,125 $0 $0 $3,305 $0 $38,430
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 02/16/2001 02/22/2001 $375 $375 $0 -  
2. 01002 Other 3664 A 02/16/2001 03/05/2001 $185 $185 $0 -  
3. 01003 Other 3660 A 02/16/2001 03/05/2001 $185 $185 $0 -  
4. 01004 Other 3661 C 02/16/2001 03/05/2001 $185 $185 $0 -  
5. 01005 Other 3668 B01 02/16/2001 03/05/2001 $185 $185 $0 -  
6. 01006 Other 5144 C01 02/16/2001 03/05/2001 $185 $185 $0 -  
7. 01007 Other 3314 G 02/16/2001 03/05/2001 $560 $560 $0 -  
8. 01008 Other 461 C 02/16/2001 03/05/2001 $375 $375 $0 -  
9. 01009 Other 14305 C 02/16/2001 03/05/2001 $325 $325 $0 -  
10. 01010 Other 23400022 A 02/16/2001 03/05/2001 $185 $185 $0 -  
11. 01011 Other 4650 H 02/16/2001 03/05/2001 $185 $185 $0 -  
12. 01012 Other 3203 B01 02/16/2001 03/21/2001 $375 $375 $0 -  
13. 02001 Serious 5162 A 02/16/2001 03/05/2001 $3,375 $3,375 $0 -  
14. 03001 Serious 23400023 02/16/2001 03/05/2001 $6,750 $6,750 $0 -  
15. 04001 Serious 23200007 B 02/16/2001 03/05/2001 $25,000 $25,000 $0 -  

Investigation Summary

Investigation Nr: 202312633
Event: 08/10/2000
Electric Shock - Contact With Energized Parts Thru Rule

An employee was using a plastic measuring tape to measure a circuit breaker bracket inside an energized panelboard. The metal hook on the measuring tape contact a busbar and caused an electrical fault. The ensuing electric arc burned the employee on his face and body. He was hospitalized for his injuries.

Keywords:burn, electric arc, e gi iv, electrical, measuring device, ppe, panelboard, electrical work, lockout, electrical fault

Investigated Inspection
# Inspection Age Sex Degree Nature Occupation
1 119689651 Hospitalized injury Burn/Scald(Heat) Supervisors, mechanics and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.