Powered by GoogleTranslate

Inspection Detail

Inspection: 119648723 - Clontech Laboratories, Inc.

Inspection Information - Office: Fremont District Office

 

Inspection Nr: 119648723
Report ID: 0950612
Date Opened: 05/12/2005

Site Address:
Clontech Laboratories, Inc.
1290 Terra Bella Ave.
Mountain View, CA 94043

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2869

NAICS: 325199/All Other Basic Organic Chemical Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/18/2005

Emphasis:

Case Closed: 07/12/2007


Related Activity
Type Activity Nr Safety Health
Accident 102450707
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 2 3
Current Violations 3 3
Initial Penalty $18,000 $0 $0 $2,250 $0 $20,250
Current Penalty $0 $0 $0 $750 $0 $750
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A 11/01/2005 11/18/2005 $0 $1,125 $0 11/29/2005 F - Formal Settlement  
2. 01002 Other 3380 A 11/01/2005 11/18/2005 $375 $1,125 $0 11/29/2005 F - Formal Settlement  
3. 02001 Other 5416 C 11/01/2005 12/04/2005 $375 $18,000 $0 11/29/2005 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202315404
Event: 05/11/2005
Employee burned in flash fire

On May 11, 2005, Employee #1 began heating up 16 liters of isopropyl alcohol (IPA) in a 5-gallon glass carboy using a hot plate. Employee #1 also used a fume hood, stirrer, and foil in the procedure, placing the foil atop the carboy opening. Employee #1 heated the IPA approximately 4 to 5 hours and observed none of the usual bubbles which appear when heating IPA. Employee #1 then raised the temperature on the hot plate and monitored the situation. At this time Employee #1 was standing in front of the fume hood, approximately 2 feet away, with the sash open. Employee #1 then removed the foil cover over the top of the carboy and within 2 to 3 minutes, the IPA started to bubble over and drip out of the carboy, approximately 5 inches down the sides and onto the hot plate. As Employee #1 attempted to disconnect the power cord to the hot plate, an explosion occurred and orange flames engulfed him. Employee #1 was hospitalized with burns.

Keywords: HEAT, ISOPROPYL ALCOHOL, FIRE, CHEMICAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 119648723 Hospitalized injury Burn(Chemical) Biological and life scientists
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close