Inspection Detail
Inspection: 119638708 - Robert Heeley, Inc.
Inspection Information - Office: Fremont District Office
Site Address:
Robert Heeley, Inc.
Sargeant Caynon Road
San Ardo, CA 93450
Mailing Address:
Po Box 3620, Paso Robles, CA 93447
Union Status: NonUnion
SIC:1389
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/23/1999
Emphasis:
Case Closed: 06/18/2007
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 101795433 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $0 | $0 | $0 | $250 | $0 | $250 |
| Current Penalty | $0 | $0 | $0 | $250 | $0 | $250 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3213 A | 11/10/1999 | 11/16/1999 | $250 | $250 | $0 | 12/02/1999 | W - Empr Withdrew |
Investigation Summary
On September 2, 1999, Employee #1, age 18, was replacing old pipeline at some hot water injection cycle pumps. For some reason, the cover of a nearby vertical pump had been removed and he stepped into an exposed section of the pipe that was full of steam and hot water. Employee #1 sustained serious burns on his left leg that would likely require skin grafting. The employer was cited for a violation of T8CCR 3212(a).
Keywords: BURN, BARRIER GUARD, WORK RULES, STEAM, PIPELINE, OIL WELL SERVICING, UNGUARDED, HOT WATER, LEG
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 119638708 | Hospitalized injury | Burn/Scald(Heat) | Construction laborers |
Translate