Powered by GoogleTranslate

Inspection Detail

Inspection: 119623809 - Sg Barber Construction, Inc

Inspection Information - Office: American Canyon District Office

 

Inspection Nr: 119623809
Report ID: 0950615
Date Opened: 05/03/2002

Site Address:
Sg Barber Construction, Inc
2 Mi North Of Ft Bragg On Hwy 1
Fort Bragg, CA 95437

Mailing Address:
1601 El Camino Real, #101, Belmont, CA 94002

Union Status: NonUnion

SIC:1521

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/29/2002

Planning Guide: Safety-Construction

Emphasis: S:Construction (Cship)

Case Closed: 08/29/2002


Related Activity
Type Activity Nr Safety Health
Accident 361596554
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $14,400 $0 $0 $0 $0 $14,400
Current Penalty $14,400 $0 $0 $0 $0 $14,400
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 8610 D 10/28/2002 05/03/2002 $14,400 $14,400 $0 11/19/2002 F - Formal Settlement  

Investigation Summary

Investigation Nr: 170842546
Event: 05/01/2002
Employee injured when aerial lift contacts power line

On May 1, 2002, Employee #1, a supervisor for a telecommunication installation contractor, was working from a Telsta T-40C aerial device mounted on a Ford F-800 truck. He was elevated to a height of approximately 27 ft, installing fiber-optic communication cable from pole to pole. The truck was being slowly driven between poles by a coworker, and Employee #1 was operating the aerial device. He was positioning the aerial lift when it contacted an energized 12-kilovolt power line. Employee #1 received an electric shock and suffered injuries that resulted in the subsequent amputation of an arm and shoulder.

Keywords: CLEARANCE, AMPUTATED, OVERHEAD POWER LINE, SHOULDER, WORK RULES, STRUCK AGAINST, CONSTRUCTION, ELECTRIC SHOCK, ARM, AERIAL LIFT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 119623809 Hospitalized injury Amputation Telephone line installers and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.