Inspection: 119582773 - Williams Steel Erection Company, Inc.
Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health
Site Address:
Williams Steel Erection Company, Inc.
156 Defense Highway
Annapolis, MD 21401
Mailing Address:
Post Office Box 506, Merrifield, VA 22116
Union Status: NonUnion
SIC:1791
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/08/1996
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 07/15/1998
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360229710 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 1 | 4 | |||
| Current Violations | 3 | 1 | 4 | |||
| Initial Penalty | $2,061 | $0 | $0 | $0 | $0 | $2,061 |
| Current Penalty | $1,500 | $0 | $0 | $0 | $0 | $1,500 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19260451 E05 | 04/16/1996 | 04/19/1996 | $500 | $687 | $0 | 05/03/1996 | F - Formal Settlement | |
| 2. | 01002 | Serious | 19260451 E09 | 04/16/1996 | 04/19/1996 | $500 | $687 | $0 | 05/03/1996 | F - Formal Settlement | |
| 3. | 01003 | Serious | 19260451 E10 | 04/16/1996 | 04/19/1996 | $500 | $687 | $0 | 05/03/1996 | F - Formal Settlement | |
| 4. | 02001 | Other | 19260020 B02 | 04/16/1996 | 04/19/1996 | $0 | $0 | $0 | 05/03/1996 | F - Formal Settlement |
Investigation Summary
Employees #1 and #2 were welding from the top level of a 20 ft 6 1/2 in. high by 5 ft wide by 7 ft long Lynn mobile propelled tubular welded scaffold. As the employees were repositioning themselves on the scaffold, it collapsed. Employee #2 attempted to hang on to the overhead joist, but fell approximately 23 ft before help could get to him. He landed on top of Employee #1, who had fallen with the scaffold. Both employees were hospitalized with fractures. The investigation found that there were no locking pins in the section connectors, and that there was no structural failure of parts. The scaffold was not equipped with a ladder access or guardrails. The employees were provided with a safety belt and lanyard; however, no fall protection was in use at the time of the accident. Employees #1 and #2 were wearing hard hats, work boots, welding clothes and gloves. No competent person inspected the scaffold.
Keywords: FRACTURE, GUARDRAIL, PIN, UNSECURED, WORK RULES, CONSTRUCTION, WELDING, SCAFFOLD COLLAPSE, FALL PROTECTION, TUBULAR SCAFFOLD
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 119582773 | Hospitalized injury | Fracture | Structural metal workers | ||
| 2 | 119582773 | Hospitalized injury | Fracture | Structural metal workers |