Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1195016.015 - Thyssenkrupp Elevator Corporation

Inspection Information - Office: Tampa Area Office

 

Inspection Nr: 1195016.015
Report ID: 0420600
Date Opened: 12/05/2016

Site Address:
Thyssenkrupp Elevator Corporation
4317 35th Street
Orlando, FL 32801

Mailing Address:
4317 35th Street, Orlando, FL 32801

Union Status: NonUnion

SIC:

NAICS: 238290/Other Building Equipment Contractors


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/05/2016

Emphasis: N:Amputate

Case Closed: 01/31/2017


Related Activity
Type Activity Nr Safety Health
Referral 1159571 Yes
Case Status: CLOSED

Investigation Summary

Investigation Nr: 92901.015
Event: 11/28/2016
Worker catches hand in elevator cables and amputates two fin

At 4:00 p.m. on November 28, 2016, Employee #1, employed by an elevator company, was engaged in auditing an elevator job. As the elevator was moving, his hand connected with the elevator cables. Emergency services were called, and Employee #1 was transported to the hospital. He was admitted and treated for the amputation of two fingertips.

Keywords: Amputation, Caught Between, Caught In, Construction, Elevator, Finger, Hand

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1195016.015 56 M Hospitalized injury Occupation Not Listed
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.