Inspection Detail
Inspection: 1187254.015 - West Seneca Town Highway Department
Inspection Information - Office: Nys Dol Pesh Buffalo
Site Address:
West Seneca Town Highway Department
28 Glenmar Dr
West Seneca, NY 14224
Mailing Address:
1250 Union Road, West Seneca, NY 14224
Union Status: Union
SIC:
NAICS: 237310/ Highway, Street, and Bridge Construction
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: LocalGovt
Safety/Health: Safety
Close Conference: 03/16/2017
Emphasis: S:Hh
Case Closed: 05/22/2017
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1150770 | Yes | |
| Accident | 1152669 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | 2 | |||
| Current Violations | 1 | 1 | 2 | |||
| Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | NYSLL ARTICLE 2, SECTION 27-A.3.A | 04/03/2017 | 05/18/2017 | $0 | $0 | $0 | Z - Issued | ||
| 2. | 02001 | Other | 12 NYCRR PART 801.39(A) | 04/03/2017 | $0 | $0 | $0 | Z - Issued |
Investigation Summary
At 9:30 a.m. on October 26, 2016, a sewer department employee was struck by and ran over by a 1997 GNC 8500 Cabover truck, with a CS10 Series Power Take Office, controlled by an Allison Transmission. The vehicle was equipped with a Safejet water jetting system that was being used to flush municipal sanitary sewers and the employee was killed.
Keywords: Crushing, Motor Vehicle, Run Over, Struck By
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1187254.015 | 53 | M | Fatality | Equipment Operator: Skidsteer/Bobcat |
Translate