Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1187002.015 - Davis Cable Technologies, L.P.

Inspection Information - Office: Dallas Area Office

 

Inspection Nr: 1187002.015
Report ID: 0626300
Date Opened: 10/26/2016

Site Address:
Davis Cable Technologies, L.P.
Fm 1461
Mckinney, TX 75071

Mailing Address:
6632 Cr 1022, Joshua, TX 76058

Union Status: NonUnion

SIC:

NAICS: 517919 


Inspection Type: Fat/Cat

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/26/2016

Emphasis:

Case Closed: 03/25/2019


Related Activity
Type Activity Nr Safety Health
Accident 1149899
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 5
Current Violations 5 5
Initial Penalty $27,886 $0 $0 $0 $0 $27,886
Current Penalty $18,120 $0 $0 $0 $0 $18,120
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100268 B07 03/31/2017 04/26/2017 $8,238 $12,675 $0 I - Informal Settlement  
2. 01001B Serious 19100268 J03 03/31/2017 04/26/2017 $0 $0 $0 I - Informal Settlement  
3. 01002 Serious 19100268 C 03/31/2017 05/18/2017 $3,291 $5,070 $0 I - Informal Settlement  
4. 01003 Serious 19100268 C03 03/31/2017 05/18/2017 $2,354 $3,622 $0 I - Informal Settlement  
5. 01004 Serious 19100268 I02 03/31/2017 04/26/2017 $1,883 $2,897 $0 I - Informal Settlement  
6. 01005 Serious 19100268 N01 I 03/31/2017 04/26/2017 $2,354 $3,622 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 89934.015
Event: 10/25/2016
Employee is electrocuted when making contact with overhead p

At 3:16 p.m. on October 25, 2016, an employee was working from a non-insulated bucket of a truck-mounted articulating telescopic aerial lift and pulling telecommunications strand with a pulling eye mounted on the bucket in order to connect the strand to a utility pole. The employee was electrocuted after something made contact with an overhead power line. The telecommunications strand was being installed 55 inches below the neutral conductor on utility poles. While installing the strand, the employee used a chain saw to trim trees in order to pull the strand through. The truck was operated by a ground hand and the employees communicated by using a two-way voice communication system from the cab to the bucket. While traveling southbound, the employee instructed the truck driver to stop. The truck driver stopped the truck and then heard two loud bangs and saw a flash of light. The employee caught fire. The truck driver used the controls at the back of the truck to lower the lift and used a fire extinguisher to put out the fire. Something had made contact with the overhead power line (14,400 volts phase to ground, 24,900 volts phase to phase). It could not be determined if the employee or the aerial lift made contact with the power line.

Keywords: Aerial Lift, Burn, Electrical, Electrocuted, Elevated Work Platform, Fire, Power Lines

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1187002.015 29 M Fatality Telecomm: Line Installers And Repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close