Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1186004.015 - 58520 - Montaplast Of North America Inc

Inspection Information - Office: Ky Labor Cabinet Division Of Osh Compliance

 

Inspection Nr: 1186004.015
Report ID: 0452110
Date Opened: 10/17/2016

Site Address:
58520 - Montaplast Of North America Inc
2011 Hoover Blvd
Hatton, KY 40601

Mailing Address:
2011 Hoover Blvd, Hatton, KY 40601

Union Status: NonUnion

SIC:3089

NAICS: 326121/Unlaminated Plastics Profile Shape Manufacturing


Inspection Type: Fat/Cat

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/16/2016

Emphasis:

Case Closed: 05/12/2017


Related Activity
Type Activity Nr Safety Health
Accident 1147354
Inspection 1328263 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $7,000 $0 $0 $0 $0 $7,000
Current Penalty $7,000 $0 $0 $0 $0 $7,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100303 B01 03/31/2017 04/13/2017 $7,000 $7,000 $0 I - Informal Settlement  
2. 02001 Other 19100147 C05 II 03/31/2017 04/10/2017 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 89809.015
Event: 10/17/2016
Engineer is electrocuted while troubleshooting equipment

At 1:00 p.m. on October 17, 2016, a 22-year old engineer was electrocuted while troubleshooting hydraulics on an injection molding machine with a hydraulic cart that provides hydraulic power independent of the IM machine. The cart is powered via 480 volt 3 phase from an adjacent IM machine. The cart will plug into the other machine via plug and cord. Some machines' plugs require an adapter. The employee was using a pigtail with a 30 amp plug on one end and a 20 amp plug on the other. The pigtail had reverse polarity in that one energized leg and was wired into the ground lug on the opposite side. This energized a portion of the cart and hydraulic hoses. The employee was handling the metal end of the hoses and was electrocuted. The origin of the pigtail is unknown at this time.

Keywords: Electrocuted, Hydraulic Crane, Molding Machine

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1186004.015 23 M Fatality Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close