Powered by GoogleTranslate

Inspection Detail

Inspection: 118115104 - General Motors Corp. (Assembly Plant)

Inspection Information - Office: Cleveland Area Office

 

Inspection Nr: 118115104
Report ID: 0522300
Date Opened: 06/01/1998

Site Address:
General Motors Corp. (Assembly Plant)
2300 Hallock Young Road
Lordstown, OH 44482

Mailing Address:
P.O. Box 1406, Warren, OH 44482

Union Status: Union

SIC:3711

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/21/1998

Emphasis:

Case Closed: 03/10/1999


Related Activity
Type Activity Nr Safety Health
Accident 100100361
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $7,000 $0 $0 $0 $0 $7,000
Current Penalty $7,000 $0 $0 $0 $0 $7,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 08/24/1998 10/26/1998 $7,000 $7,000 $0 09/14/1998 F - Formal Settlement  

Investigation Summary

Investigation Nr: 200100303
Event: 05/31/1998
Employee killed when struck by combustion air turbulator

Employee #1, a pipe fitter, and two coworkers were relighting a zone in an ELPO (electrophoretic) phosphate oven when an explosion occurred. The combustion air turbulator was blown off and struck Employee #1, killing him. Subsequent investigation revealed that there had been no proven purge to remove any buildup of natural gas during lighting of the individual zones after an individual burner shut down. In addition, explosion relief vents had not been installed; a preventative maintenance program, including inspection and operational checks, was not in place as per the manufacturers' recommendations; and the employees operating and maintaining the oven had not received initial or periodic training in accordance with NFPA 86 standards for ovens and furnaces.

Keywords: VENTILATION, FLAMMABLE VAPORS, OVEN, WORK RULES, NATURAL GAS, EXPLOSION, STRUCK BY, FLYING OBJECT, UNTRAINED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 118115104 Fatality Cut/Laceration Plumbers, pipefitters and steamfitters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close