Powered by GoogleTranslate

Inspection Detail

Inspection: 1169036 - Glenns Pool Service Inc

Inspection Information - Office: Fort Lauderdale Area Office

 

Inspection Nr: 1169036
Report ID: 0418800
Date Opened: 09/12/1984

Site Address:
Glenns Pool Service Inc
6391 Allison Rd
Miami Bch, FL 33141

Mailing Address:
360 N W 190 St, Miami, FL 33169

Union Status: NonUnion

SIC:1721

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/18/1984

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 10/11/1984


Related Activity
Type Activity Nr Safety Health
Accident 360563951
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $180 $0 $0 $0 $0 $180
Current Penalty $180 $0 $0 $0 $0 $180
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260400 H01 09/21/1984 09/24/1984 $180 $180 $0 -  
2. 01001B Serious 19260401 A01 09/21/1984 09/24/1984 $0 $0 $0 -  
3. 02001 Other 19260300 D02 09/21/1984 09/24/1984 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14525893
Event: 09/10/1984
ELECTRIC SHOCK - ELECTRIC DRILL FRAME ENERGIZED BY ADAPTER

AN EMPLOYEE WAS INSTALLING A COVER AT THE BOTTOM DRAIN OF AN EMPTY SWIMMING POOL. HE WAS USING AN ELECTRIC DRILL WITH A THREE-CONDUCTOR CORD SET PLUGGED INTO A GROUNDING-TYPE RECEPTACLE OUTLET. BETWEEN THE THREE-PRONGED PLUG ON THE DRILL'S PENDANT CORD AND THE CORD CONNECTOR (RECEPTACLE) ON THE CORD SET WAS AN ADAPTER DESIGNED TO PROVIDE A GROUNDING MEANS FOR UNGROUNDED RECEPTACLES. THIS ADAPTER HAD A TAB, WITH A HOLE FOR THE RECEPTACLE FACE PLATE SCREW, WHICH WAS BENT OVER AND WAS IN CONTACT WITH THE UNGROUNDED PRONG OF THE ADAPTER. THE EMPLOYEE, WHO WAS WEARING RUBBER-SOLED SHOES, APPARENTLY KNELT ON THE CONCRETE POOL BOTTOM TO DRILL HOLES IN THE FLANGE OF THE DRAIN PIPE. HE RECEIVED A FATAL ELECTRIC SHOCK FROM THE METAL DRILL CASE, WHICH HAD BECOME ENERGIZED THROUGH THE GROUNDING TAB OF THE ADAPTER.

Keywords: ELECTRICAL, CORD SET, ELECTROCUTED, ATTACHMENT PLUG, E C, ELECTRIC DRILL, PLUG ADAPTER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1169036 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close