Inspection Detail
Inspection: 116317215 - Alan Ritchey, Inc.
Inspection Information - Office: Fort Worth Area Office
Site Address:
Alan Ritchey, Inc.
740 S. I 35e Service Rd.
Valley View, TX 76272
Mailing Address:
Po Box 249, Valley View, TX 76272
Union Status: NonUnion
SIC:2048
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/13/1995
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 06/06/1997
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360377717 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $5,000 | $0 | $0 | $0 | $0 | $5,000 |
Current Penalty | $2,500 | $0 | $0 | $0 | $0 | $2,500 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001A | Serious | 19100332 B01 | 10/26/1995 | 11/07/1995 | $2,500 | $5,000 | $0 | J - ALJ Decision | ||
2. | 01001B | Serious | 19100145 C03 | 10/26/1995 | 11/07/1995 | $0 | $0 | $0 | J - ALJ Decision | ||
3. | 01001C | Serious | 19100333 C03 IIIA | 10/26/1995 | 11/07/1995 | $0 | $0 | $0 | J - ALJ Decision |
Investigation Summary
An employee of a feed manufacturing company was operating a boom-type screw conveyor. The conveyor contacted a 7200-volt overhead power line, and the employee was electrocuted.
Keywords: OVERHEAD POWER LINE, ELECTRICAL, BOOM, SCREW CONVEYOR, ELECTROCUTED, E GI IA
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 116317215 | Fatality | Electric Shock | Occupation not reported |