Inspection Detail
Inspection: 116309378 - Strategic Materials, Inc.
Inspection Information - Office: Dallas Area Office
Site Address:
Strategic Materials, Inc.
2521 Royal Ln.
Dallas, TX 75229
Mailing Address:
249 Robertson Rd., Midlothian, TX 76065
Union Status: NonUnion
SIC:3229
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/26/1996
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 02/26/1998
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 100780022 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 3 | 1 | 4 | |||
Current Violations | 2 | 2 | ||||
Initial Penalty | $13,500 | $63,000 | $0 | $0 | $0 | $76,500 |
Current Penalty | $9,000 | $0 | $0 | $0 | $0 | $9,000 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100332 B01 | 01/09/1997 | 01/16/1997 | $0 | $4,500 | $0 | 01/17/1997 | F - Formal Settlement | Citation has been deleted. |
2. | 01002 | Serious | 19100333 C03 | 01/09/1997 | 01/16/1997 | $4,500 | $4,500 | $0 | 01/17/1997 | F - Formal Settlement | |
3. | 01003 | Serious | 19100333 C03 IIIB | 01/09/1997 | 01/16/1997 | $0 | $4,500 | $0 | 01/17/1997 | F - Formal Settlement | Citation has been deleted. |
4. | 02001 | Serious | 19100333 C03 IIIA | 01/09/1997 | 01/16/1997 | $4,500 | $63,000 | $0 | 01/17/1997 | F - Formal Settlement |
Investigation Summary
An employee was loading a 6.7-meter-long dumpster containing broken glass onto a roll-off hoist trailer, which was parked under an overhead power line. He connected the hoist cable to the hook installed on the front of the dumpster and tilted the trailer upwards about 8 meters above ground level. As the winch reeled in the hoist cable, the hook pulled out of the reinforced steel plate, flew into the air still connected to the hoist cable, and wrapped around two of the three phase conductors of the overhead power line. This energized the trailer and electrocuted the employee.
Keywords: OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, DUMPSTER, E GI IA, EQUIPMENT FAILURE, LOAD LINE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 116309378 | Fatality | Electric Shock | Occupation not reported |