Inspection Detail
Inspection: 116301367 - Battery Engineering, Incorporated
Inspection Information - Office: Boston South Area Office
Site Address:
Battery Engineering, Incorporated
1636 Hyde Park Avenue
Boston, MA 02136
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3679
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 04/29/1997
Emphasis:
Case Closed: 04/29/1997
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 100460054 |
Investigation Summary
Employees #1 and #2 were engaged in the regular jobs when a Double D cell battery detonated, and overpressurized a cell nearby. They were transported to the hospital, where they were treated for lacerations and for skin contact with carbon black (a component of the cells), lithium chips, and thionyl chloride. Three coworkers were also taken to the hospital complaining of ringing in their ears.
Keywords: BATTERY, CAUSTIC, EXPLOSION, LACERATION, HIGH PRESSURE, CHEMICAL BURN, SKIN, CHEMICAL
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 116301367 | Hospitalized injury | Burn(Chemical) | Electrical and electronic equipment assemblers | ||
2 | 116301367 | Hospitalized injury | Burn(Chemical) | Supervisors, production occupations |