Inspection Detail
Inspection: 116042375 - Cng Transmission Corporation
Inspection Information - Office: Pittsburgh Area Office
Site Address:
Cng Transmission Corporation
Well Site Uw103
Hopwood, PA 15445
Mailing Address:
P.O. Box 2450, 445 West Main Street, Clarksburg, WV 26302
Union Status: Union
SIC:4922
NAICS: 0
Inspection Type: Unprog Rel
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 11/16/1992
Emphasis:
Case Closed: 08/05/1994
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360844609 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 3 | 2 | 5 | |||
Current Violations | 3 | 3 | ||||
Initial Penalty | $11,000 | $140,000 | $0 | $0 | $0 | $151,000 |
Current Penalty | $16,000 | $0 | $0 | $0 | $0 | $16,000 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001A | Serious | 19100023 A06 | 11/30/1992 | 12/14/1992 | $7,000 | $7,000 | $0 | 12/17/1992 | F - Formal Settlement | Citation has been deleted. |
2. | 01001B | Serious | 19100023 C01 | 11/30/1992 | 12/14/1992 | $0 | $0 | $0 | 12/17/1992 | F - Formal Settlement | Citation has been deleted. |
3. | 01002 | Serious | 19100027 B01 II | 11/30/1992 | 12/14/1992 | $2,000 | $2,000 | $0 | 12/17/1992 | F - Formal Settlement | |
4. | 01003 | Serious | 19100151 C | 11/30/1992 | 12/14/1992 | $2,000 | $2,000 | $0 | 12/17/1992 | F - Formal Settlement | Citation has been deleted. |
5. | 02001 | Serious | 5A0001 | 11/30/1992 | 12/14/1992 | $7,000 | $70,000 | $0 | 12/17/1992 | F - Formal Settlement | |
6. | 02002A | Serious | 19101200 E01 II | 11/30/1992 | 12/14/1992 | $7,000 | $70,000 | $0 | 12/17/1992 | F - Formal Settlement | |
7. | 02002B | Serious | 19101200 F05 I | 11/30/1992 | 12/14/1992 | $0 | $0 | $0 | 12/17/1992 | F - Formal Settlement | |
8. | 02002C | Serious | 19101200 F05 II | 11/30/1992 | 12/14/1992 | $0 | $0 | $0 | 12/17/1992 | F - Formal Settlement | |
9. | 02002D | Serious | 19101200 G08 | 11/30/1992 | 12/03/1992 | $0 | $0 | $0 | 12/17/1992 | F - Formal Settlement | |
10. | 02002E | Serious | 19101200 H | 11/30/1992 | 12/14/1992 | $0 | $0 | $0 | 12/17/1992 | F - Formal Settlement |
Investigation Summary
On the morning of June 3, 1992, the bodies of Employees #1 and #2 were found by coworkers inside a tank truck used to recover gas well fracing chemicals. The cause of death was listed as asphyxiation due to exposure to acid fumes and oxygen deprivation. At the time of the accident, 1 1/2 million cubic feet of nitrogen gas, which was used in the fracing process, was being piped from the wellhead to the tank to recover fracing chemicals, including hydrochloric and acidic acids. Willful citations were issued to two employers for confined space entry and hazard communication deficiencies, along with other alleged violations. A third employer was issued a citation for hazard communication deficiencies under the multi-employer workplace provision in the standard.
Keywords: OXYGEN DEFICIENCY, ASPHYXIATED, TOXIC FUMES, HYDROCHLORIC ACID, FRAC TANK, WORK RULES, CONFINED SPACE, OIL WELL DRILLING, NITROGEN, COMMUNICATION
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 116042375 | Occupation Not Listed |