Inspection Detail
Inspection: 115952129 - Jim Beam Brands Co.
Inspection Information - Office: Ky Labor Cabinet Division Of Osh Compliance
Site Address:
Jim Beam Brands Co.
526 Happy Hollow Rd
Clermont, KY 40110
Mailing Address:
P O Box 160, Clermont, KY 40110
Union Status: Union
SIC:2085
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/03/1991
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 03/17/1993
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 361067150 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $560 | $0 | $0 | $0 | $0 | $560 |
Current Penalty | $560 | $0 | $0 | $0 | $0 | $560 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100333 A | 12/06/1991 | 12/13/1991 | $560 | $560 | $0 | - |
Investigation Summary
AN EMPLOYEE WAS PERFORMING MAINTENANCE ON A GLUE MACHINE. THE CONNECTOR FOR THE MACHINE HAD A MANUFACTURING DEFECT THAT ENERGIZED THE CONNECTOR BODY. THE EMPLOYEE WAS ELECTROCUTED.
Keywords: ELECTRICAL, E GI VII, ELECTROCUTED, ATTACHMENT PLUG, CORD CONNECTOR
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 115952129 | Fatality | Electric Shock | Occupation not reported |