Powered by GoogleTranslate

Inspection Detail

Inspection: 115950826 - Louisville Emergency Medical Service

Inspection Information - Office: Ky Labor Cabinet Division Of Osh Compliance

 

Inspection Nr: 115950826
Report ID: 0452110
Date Opened: 09/17/1991

Site Address:
Louisville Emergency Medical Service
1805 S Brook St
Louisville, KY 40208

Mailing Address:
, , 00000

Union Status: Union

SIC:9229

NAICS: 0 


Inspection Type: Unprog Rel

Scope: Partial

Advanced Notice: N

Ownership: LocalGovt

Safety/Health: Health

Close Conference: 04/13/1992

Emphasis:

Case Closed: 12/21/1992


Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 2 3
Current Violations 2 2
Initial Penalty $420 $0 $0 $60 $0 $480
Current Penalty $0 $0 $0 $60 $0 $60
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100132 A 05/08/1992 05/20/1992 $420 $420 $0 06/01/1992 F - Formal Settlement Citation has been deleted.
2. 02001A Other 19100134 B06 05/08/1992 05/14/1992 $60 $60 $0 06/01/1992 F - Formal Settlement  
3. 02001B Other 19100134 B10 05/08/1992 06/10/1992 $0 $0 $0 06/01/1992 F - Formal Settlement  
4. 02002A Other 19101200 E01 05/08/1992 06/10/1992 $0 $0 $0 06/01/1992 F - Formal Settlement  
5. 02002B Other 19101200 G08 05/08/1992 05/13/1992 $0 $0 $0 06/01/1992 F - Formal Settlement  
6. 02002C Other 19101200 H01 05/08/1992 05/20/1992 $0 $0 $0 06/01/1992 F - Formal Settlement  

Investigation Summary

Investigation Nr: 783886
Event: 09/12/1991
Employees suffer skin and eye irritation from sulfur dioxide

At approximately 11:00 p.m. on September 10, 1991, three employees arrived to perform maintenance on a furnace equipped with a 150 lb compressed gas cylinder of sulfur dioxide. A shipping crew of nine employees was working at the opposite end of the plant, 300 ft away. Heat from the furnace caused the fusible safety device in the cylinder valve to melt and release approximately 15 lb of sodium dioxide. The three employees attempted to stop the release. When their attempts failed, they transported the cylinder outside, passing by the shipping crew employees. The Louisville Fire Department arrived and capped the cylinder. One maintenance employee and seven shipping crew employees were taken to the hospital. They were treated for pulmonary and skin and eye irritation caused by the sulfur dioxide fumes.

Keywords: CYLINDER, SULFUR DIOXIDE, VALVE, TOXIC FUMES, EYE, MAINTENANCE, GAS, SKIN

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 115950826 Occupation Not Listed
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close