Powered by GoogleTranslate

Inspection Detail

Inspection: 115747271 - Glenbrook Nickel Company & Cominco American Inc

Inspection Information - Office: Medford

 

Inspection Nr: 115747271
Report ID: 1054116
Date Opened: 11/20/1991

Site Address:
Glenbrook Nickel Company & Cominco American Inc
5093 Riddle Bypass Rd
Riddle, OR 97469

Mailing Address:
Po Box 85, Riddle, OR 97469

Union Status: NonUnion

SIC:3315

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/17/1991

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 05/29/1992


Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 6 6
Current Violations 5 5
Initial Penalty $12,000 $0 $0 $0 $0 $12,000
Current Penalty $6,350 $0 $0 $0 $0 $6,350
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 740003002 B 01/09/1992 01/12/1992 $2,500 $2,500 $0 01/27/1992 L - State Settlement  
2. 01002 Serious 789033519 01/09/1992 01/12/1992 $1,000 $2,500 $0 01/27/1992 L - State Settlement  
3. 01003 Serious 789001502 D 01/09/1992 01/12/1992 $2,500 $2,500 $0 01/27/1992 L - State Settlement Citation has been deleted.
4. 01004 Serious 789032502 01/09/1992 01/12/1992 $1,500 $2,500 $0 01/27/1992 L - State Settlement  
5. 01005A Serious 789001010 01/09/1992 11/20/1991 $1,200 $1,200 $0 01/27/1992 L - State Settlement  
6. 01005B Serious 789029001 01/09/1992 11/20/1991 $0 $0 $0 01/27/1992 L - State Settlement  
7. 01006 Serious 789001501 01/09/1992 11/20/1991 $150 $800 $0 01/27/1992 L - State Settlement  

Investigation Summary

Investigation Nr: 711044
Event: 11/18/1991
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU LOAD

SOME MAINTENANCE EMPLOYEES FOR A METALS COMPANY WERE UNLOADING A 37-FOOT-LONG CLASSIFIER TUB IN A STORAGE YARD. A 13.8-KILOVOLT OVERHEAD POWER LINE WAS LOCATED ABOVE THE YARD. THE EMPLOYEES WERE USING A 20-TON P&H WHEEL-MOUNTED CRANE TO LIFT AND POSITION THE TUB. THE CRANE WAS LOCATED ABOUT 15 TO 20 FEET AWAY FROM THE POWER LINE. NO TAGS LINES WERE USED TO CONTROL THE LOAD, NOR WAS A SIGNALER USED TO DIRECT THE CRANE OPERATOR. THE TRAILER HOLDING THE TUB WAS POSITIONED IN FRONT OF THE CRANE TO KEEP THE OPERATING RADIUS AND BOOM AS SHORT AS POSSIBLE. AS THE CLASSIFIER WAS BEING LIFTED, BUT BEFORE IT WAS FULLY SUSPENDED, THE LOADER OPERATOR PULLED THE TRAILER OUT FROM UNDER THE LOAD. THIS CAUSED THE LOAD TO DROP SLIGHTLY AND SWING TOWARD THE CRANE AND THE POWER LINE. ONE OF THE EMPLOYEES REACTED BY GRABBING A HYDRAULIC HOSE ON THE CLASSIFIER IN AN ATTEMPT TO KEEP IT FROM SWINGING INTO THE CRANE. AT ABOUT THE SAME TIME, THE OTHER END OF THE CLASSIFIER CONTACTED THE POWER LINE. THE EMPLOYEE HOLDING THE HOSE RECEIVED AN ELECTRIC SHOCK AND COLLAPSED SHORTLY AFTERWARDS. THE EMPLOYEE WAS HOSPITALIZED FOR SEVERAL DAYS FOR OBSERVATION.

Keywords: UNCONSCIOUSNESS, OVERHEAD POWER LINE, ELECTRICAL, SUSPENDED LOAD, E GI IA, ELECTRIC SHOCK, CRANE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 115747271 Hospitalized injury Electric Shock Miscellaneous material moving equipment operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.