Powered by GoogleTranslate

Inspection Detail

Inspection: 115711020 - Brad L Santucci & Shelly Santucci

Inspection Information - Office: Or-E-Salem 1054100

 

Inspection Nr: 115711020
Report ID: 1054118
Date Opened: 06/01/1993

Site Address:
Brad L Santucci & Shelly Santucci
Mile Post 5 Mckay Rd North Side
Prineville, OR 97754

Mailing Address:
304040 Daycreek Rd, Prineville, OR 97754

Union Status: NonUnion

SIC:0191

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/11/1993

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 12/07/1999


Related Activity
Type Activity Nr Safety Health
Accident 362316424
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2 3 7
Current Violations 2 2 3 7
Initial Penalty $5,300 $20,000 $0 $400 $0 $25,700
Current Penalty $3,200 $3,000 $0 $300 $0 $6,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 7155003001 A 08/20/1993 08/23/1993 $200 $300 $0 08/23/1993 L - State Settlement  
2. 01002 Serious 7810753 08/20/1993 08/23/1993 $3,000 $5,000 $0 08/23/1993 L - State Settlement  
3. 02003 Willful 7810023 08/20/1993 08/23/1993 $3,000 $10,000 $0 08/23/1993 L - State Settlement  
4. 02004 Willful 7810033 08/20/1993 08/23/1993 $0 $10,000 $0 08/23/1993 L - State Settlement  
5. 03005 Other 7155002501 08/20/1993 08/23/1993 $0 $0 $0 08/23/1993 L - State Settlement  
6. 03007 Other 19100147 C01 08/20/1993 08/23/1993 $100 $150 $0 08/23/1993 L - State Settlement  
7. 03008 Other 701005201 08/20/1993 08/23/1993 $200 $250 $0 08/23/1993 L - State Settlement  

Investigation Summary

Investigation Nr: 789685
Event: 05/25/1993
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU METAL PIPE

An employee was setting up an aluminum irrigation pipe on a 50-acre field. When he retrieved the first 40-foot-long section of pipe, he noticed a rodent inside the pipe. He upended the pipe to let the rodent out before he connected the pipe. The pipe contacted a 7200-volt overhead power line that was located directly above him. The employee was electrocuted.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, IRRIGATION PIPE, E GI IC, METAL PIPE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 115711020 Fatality Electric Shock Farm workers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close