Inspection Detail
Inspection: 115547390 - James River Corp
Inspection Information - Office: Dosh Tumwater Service Location, Tumwater, Wa
Site Address:
James River Corp
4th & Adams
Camas, WA 98607
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:2621
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/03/1991
Emphasis:
Case Closed: 06/04/1991
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361031586 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $400 | $0 | $0 | $0 | $0 | $400 |
| Current Penalty | $400 | $0 | $0 | $0 | $0 | $400 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 0790022002 A | 05/15/1991 | 04/03/1991 | $400 | $400 | $0 | - |
Investigation Summary
Employees #1 and #2 were disassembling a stock transfer pump at the #1 paper machine brake storage chest. Neither worker was aware that the brake chest was filled with water between 170 and 180 degrees F. The isolation valve pipe from the chest to the pump was not closed and locked out. When the bolts on the pump were loosened, the hot water escaped, scalding both workers.
Keywords: BURN, DISMANTLING, WORK RULES, LOCKOUT, VALVE, PAPER MACHINE, PUMP, ACCIDENTAL DISCHARGE, HOT WATER
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 115547390 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | ||
| 2 | 115547390 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |
Translate