Inspection Detail
Inspection: 115537748 - Plum Creek Remanufacturing Jv
Inspection Information - Office: Dosh Spokane Service Location, Spokane, Wa
Site Address:
Plum Creek Remanufacturing Jv
N 3308 Sullivan Rd - Bldg #27
Spokane, WA 99216
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:2421
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/27/1992
Emphasis: L:Euc
Case Closed: 02/27/1992
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 361204522 |
Investigation Summary
AN EMPLOYEE WAS TROUBLESHOOTING THE ELECTRICAL CONTROLS FOR AN R. F. GENERATOR. SOME 350-AMPERE FUSES AND OTHER PARTS OF THE GENERATOR CIRCUIT ENERGIZED AT 480 VOLTS WERE EXPOSED NEAR WHERE THE EMPLOYEE WAS WORKING. AS THE EMPLOYEE WAS TESTING THE EQUIPMENT, HIS BODY TURNED TO THE RIGHT, NEARLY PARALLEL TO THE FUSES. HIS RIGHT ARM CONTACTED AN ENERGIZED PART AND CAUSED AN ELECTRIC ARC. THE EMPLOYEE, WHO WAS HOSPITALIZED FOR HIS INJURIES, RECEIVED AN ELECTRIC SHOCK AND FIRST AND SECOND DEGREE BURNS ON HIS RIGHT ARM, HAND, EAR, AND SHOULDER AND ON HIS FACE AND LEFT HAND. THE EMPLOYEE WAS WORKING ALONE. THERE WERE NO WITNESSES, AND THE EMPLOYEE COULD NOT REMEMBER EXACTLY WHAT HE WAS DOING AT THE TIME OF THE ACCIDENT.
Keywords: BURN, CLOTHING, ELECTRIC ARC, E GI IV, ELECTRICAL, ELECTRICIAN, ELECTRICAL WORK, LOCKOUT, ELECTRIC SHOCK, ELECTRICAL FAULT
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 115537748 | Hospitalized injury | Burn/Scald(Heat) | Electricians |