Inspection Detail
Inspection: 115523789 - Falcon Telecable
Inspection Information - Office: Dosh Yakima Service Location, Yakima, Wa
Site Address:
Falcon Telecable
4519 Se Mile Hill Dr
Port Orchard, WA 98366
Mailing Address:
474 S Raymond, Pasadena, CA 91106
Union Status: NonUnion
SIC:7389
NAICS: 0
Inspection Type: Referral
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/21/1994
Emphasis: L:Euc
Case Closed: 09/21/1994
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 900480328 | Yes |
Investigation Summary
Employee #1 was repairing a broken TV cable in a trench about 12 in. wide by 24 in. long by 18 in. deep. He spliced the cable at one end, put a plastic sleeve over the splice, and heated it with a propane torch to shrink it, sealing it from moisture. He went to his truck to get something and then proceeded to the other end of the trench. That is all he can remember. Apparently, he blacked out and fell over the trench with the lit torch, and burned his left hand and torso.
Keywords: BURN, UNCONSCIOUSNESS, REPAIR, CABLE TV WORK, TORSO, TRENCH, PROPANE TORCH, FALL, HAND
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 115523789 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |
Translate