Inspection Detail
Inspection: 115475105 - Sturm Heating Co Inc
Inspection Information - Office: Dosh Spokane Service Location, Spokane, Wa
Site Address:
Sturm Heating Co Inc
N 2504 Perry
Spokane, WA 99207
Mailing Address:
204 E Indiana, Spokane, WA 99207
Union Status: NonUnion
SIC:1711
NAICS: 0
Inspection Type: Referral
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/31/1994
Emphasis: L:Wasafety
Case Closed: 12/19/1994
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 900479916 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 9 | 4 | 13 | |||
| Current Violations | 9 | 4 | 13 | |||
| Initial Penalty | $5,930 | $0 | $0 | $0 | $0 | $5,930 |
| Current Penalty | $1,500 | $0 | $0 | $0 | $0 | $1,500 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 1550042801 A | 09/30/1994 | 08/31/1994 | $300 | $1,575 | $0 | 10/18/1994 | L - State Settlement | |
| 2. | 01002A | Serious | 0241800304 | 09/30/1994 | 08/31/1994 | $150 | $630 | $0 | 10/18/1994 | L - State Settlement | |
| 3. | 01002B | Serious | 0241800509 | 09/30/1994 | 08/31/1994 | $0 | $0 | $0 | 10/18/1994 | L - State Settlement | |
| 4. | 01003 | Serious | 0241500103 B | 09/30/1994 | 08/31/1994 | $150 | $700 | $0 | 10/18/1994 | L - State Settlement | |
| 5. | 01004 | Serious | 0242050901 | 09/30/1994 | 08/31/1994 | $150 | $450 | $0 | 10/18/1994 | L - State Settlement | |
| 6. | 01005 | Serious | 0246820302 B | 09/30/1994 | 08/31/1994 | $150 | $450 | $0 | 10/18/1994 | L - State Settlement | |
| 7. | 01006 | Serious | 0247350301 | 09/30/1994 | 08/31/1994 | $150 | $625 | $0 | 10/18/1994 | L - State Settlement | |
| 8. | 01007 | Serious | 0247500701 | 09/30/1994 | 08/31/1994 | $150 | $500 | $0 | 10/18/1994 | L - State Settlement | |
| 9. | 01008 | Serious | 0247500901 | 09/30/1994 | 08/31/1994 | $150 | $500 | $0 | 10/18/1994 | L - State Settlement | |
| 10. | 01009A | Serious | 0249560901 A 01 | 09/30/1994 | 10/08/1994 | $150 | $500 | $0 | 10/18/1994 | L - State Settlement | |
| 11. | 01009B | Serious | 0249560902 B | 09/30/1994 | 10/08/1994 | $0 | $0 | $0 | 10/18/1994 | L - State Settlement | |
| 12. | 01009C | Serious | 0249560910 A 01 | 09/30/1994 | 10/08/1994 | $0 | $0 | $0 | 10/18/1994 | L - State Settlement | |
| 13. | 02001 | Other | 0245500501 | 09/30/1994 | 08/31/1994 | $0 | $0 | $0 | 10/18/1994 | L - State Settlement | |
| 14. | 02002 | Other | 02465703 | 09/30/1994 | 08/31/1994 | $0 | $0 | $0 | 10/18/1994 | L - State Settlement | |
| 15. | 02003 | Other | 0247350901 | 09/30/1994 | 11/02/1994 | $0 | $0 | $0 | 10/18/1994 | L - State Settlement | |
| 16. | 02004 | Other | 0247950702 G | 09/30/1994 | 08/31/1994 | $0 | $0 | $0 | 10/18/1994 | L - State Settlement |
Investigation Summary
An employee was troubleshooting an air conditioner at a residence. The unit was located about 230 millimeters from the house, and the only way to access its components was through the back of the unit, next to the house. Kneeling on damp ground and with his upper body resting against the grounded case of the unit, the employee reached inside the back of the air conditioner to see if the compressor lines were hot. The employee apparently contacted a run capacitor energized at 377 volts, received an electric shock, and was rendered unconscious, with cardiovascular and respiratory failure. The home owners deenergized the air conditioner and, with the help of a neighbor, administered cardiopulmonary resuscitation until emergency medical services arrived. The employee, who had been revived, was hospitalized for his injury.
Keywords: E GI II, ELEC PROTECT EQUIP, REPAIR, ELECTRICAL, CPR, AIR CONDITIONER, ELECTROCUTED, CAPACITOR
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 115475105 | Hospitalized injury | Electric Shock | Heating, air conditioning, and refrig. mechanics |
Translate