Inspection Detail
Inspection: 115277717 - Burnham Insulation Inc
Inspection Information - Office: Dosh Seattle Service Location, Seattle, Wa
Site Address:
Burnham Insulation Inc
7250 S 228th St
Kent, WA 98032
Mailing Address:
Po Box 2468, Redmond, WA 98073
Union Status: NonUnion
SIC:1742
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/06/1996
Emphasis:
Case Closed: 09/06/1996
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361208572 |
Investigation Summary
At 1:30 p.m. on August 22, 1996, Employee #1 was operating an Ivy Hi-Lift to install insulation brackets in the ceiling of an Amway warehouse. He had the boom of the lift turned to the back side of the base platform, a position in which the operating controls are reversed. Employee #1 was elevated to the roof and was snug against a rafter. He apparently wanted to move away from the rafter and pushed forward on the control lever to move forward. With the controls reversed, he was actually pushing against the rafter instead. Employee #1's body was pressed against the control lever and he became caught between the lift basket and the rafter. He was unable to free himself and he died of asphyxia.
Keywords: ASPHYXIATED, INSTALLING, WORK RULES, CONSTRUCTION, CAUGHT BETWEEN, CRUSHED, ELEVATED WORK PLAT, AERIAL LIFT
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 115277717 | Fatality | Asphyxia | Occupation not reported |