Powered by GoogleTranslate

Inspection Detail

Inspection: 115084055 - Mogensen Steel Erectors, Inc.

Inspection Information - Office: Iowa 0751910

 

Inspection Nr: 115084055
Report ID: 0751910
Date Opened: 09/09/1997

Site Address:
Mogensen Steel Erectors, Inc.
5 Miles South Of Junction 3 & 69
Clarion, IA 50525

Mailing Address:
Box 401, Clarion, IA 50525

Union Status: NonUnion

SIC:1791

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/10/1997

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 04/08/1998


Related Activity
Type Activity Nr Safety Health
Accident 360696843
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $7,500 $0 $0 $0 $0 $7,500
Current Penalty $3,750 $0 $0 $0 $0 $3,750
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260021 B02 10/22/1997 12/15/1997 $1,250 $2,500 $0 I - Informal Settlement  
2. 01002 Serious 19260416 A03 10/22/1997 12/15/1997 $1,250 $2,500 $0 I - Informal Settlement  
3. 01003 Serious 19260602 C01 VII 10/22/1997 10/27/1997 $1,250 $2,500 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 170568521
Event: 09/08/1997
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

Two employees were moving wire mesh mats to another location at a worksite. They were handling the mats by suspending them from the forks of a machine. The boom on the machine was at or near full extension to keep the mats from dragging on the ground. One of the two employees was driving the machine, and the other (the brother of the first employee) was riding on the side of the machine as it passed under an overhead power line. The top part of the backrest contacted the power line. The rider jumped off. The driver tried to do the same, but apparently touched the ground and the machine at the same time. He received an electric shock and sustained severe electrical burns. He was pronounced dead of his injuries at the hospital. His coworker sustained burns trying to help the injured driver, but refused treatment.

Keywords: BURN, OVERHEAD POWER LINE, ELECTRICAL, BOOM, CONSTRUCTION, E C, INDUSTRIAL TRUCK, ELECTRIC SHOCK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 115084055 Non Hospitalized injury Electric Shock Structural metal workers
2 115084055 Fatality Electric Shock Structural metal workers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.