Powered by GoogleTranslate

Inspection Detail

Inspection: 115076507 - Keokuk Ferro-Sil, Inc.

Inspection Information - Office: Iowa 0751910

 

Inspection Nr: 115076507
Report ID: 0751910
Date Opened: 09/19/1995

Site Address:
Keokuk Ferro-Sil, Inc.
Commercial Street
Keokuk, IA 52632

Mailing Address:
P. O. Box 527, Keokuk, IA 52632

Union Status: NonUnion

SIC:3313

NAICS: 0 


Inspection Type: Complaint

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/25/1995

Emphasis:

Case Closed: 02/09/1996


Related Activity
Type Activity Nr Safety Health
Complaint 77520203 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 11 11
Current Violations 11 11
Initial Penalty $13,285 $0 $0 $0 $0 $13,285
Current Penalty $9,435 $0 $0 $0 $0 $9,435
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100022 D01 11/09/1995 12/29/1995 $1,925 $1,925 $0 -  
2. 01002A Serious 19100023 C01 11/09/1995 12/29/1995 $770 $770 $0 -  
3. 01002B Serious 19100023 C02 11/09/1995 11/15/1995 $0 $0 $0 -  
4. 01003 Serious 19100147 C02 II 11/09/1995 12/29/1995 $642 $1,925 $0 I - Informal Settlement  
5. 01004 Serious 19100147 D05 I 11/09/1995 12/29/1995 $642 $1,925 $0 I - Informal Settlement  
6. 01005 Serious 19100147 F03 II 11/09/1995 12/29/1995 $641 $1,925 $0 I - Informal Settlement  
7. 01006 Serious 19100212 A01 11/09/1995 12/29/1995 $578 $578 $0 -  
8. 01007 Serious 19100219 F03 11/09/1995 12/29/1995 $963 $963 $0 -  
9. 01008 Serious 19100252 A02 II 11/09/1995 12/29/1995 $770 $770 $0 -  
10. 01009 Serious 19100303 G02 I 11/09/1995 12/29/1995 $963 $963 $0 -  
11. 01010A Serious 19100305 A01 I 11/09/1995 12/29/1995 $578 $578 $0 -  
12. 01010B Serious 19100305 B02 11/09/1995 11/15/1995 $0 $0 $0 -  
13. 01011A Serious 19100305 G01 III 11/09/1995 11/15/1995 $963 $963 $0 -  
14. 01011B Serious 19100305 G01 III 11/09/1995 12/29/1995 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 171048259
Event: 09/19/1995
Employee injured by explosion inside electric arc furnace

On July 30, 1995, Employee #1 was working on top of an electric arc furnace repairing a water cooled electrical contact on an arc electrode. According to the furnace operator, a water leak was causing material that was being fed into the furnace to plug, and water to enter the furnace. At 8:51 a.m., the furnace was shut down for repair. While Employee #1 was at the work site, a coworker went into the control room and lowered the electrode. At this time, an explosion occurred in the furnace, causing 2nd- and 3rd-degree burns to Employee #1. The ambulance service received the 911 call at 10:20 a.m. Employee #1 was hospitalized. Company officials think the lowering of the electrode forced water into molten steel and silica material, resulting in the explosion.

Keywords: BURN, FURNACE, LEAK, ELECTRIC ARC, REPAIR, WORK RULES, EXPLOSION, MOLTEN METAL, WATER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 115076507 Hospitalized injury Burn/Scald(Heat) Industrial machinery repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.