Inspection Detail
Inspection: 114942147 - Norris Brothers Inc
Inspection Information - Office: Indiana Department Of Labor
Site Address:
Norris Brothers Inc
(Lilly Technology Center South)1555 Kentucky Ave
Indianapolis, IN 46204
Mailing Address:
Attn Mike Geoffrion 2916 Bluff Road, Indianapolis, IN 46225
Union Status: Union
SIC:1629
NAICS: 0
Inspection Type: Unprog Rel
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/02/1992
Emphasis: N:Trench
Case Closed: 12/21/1995
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 361312382 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $3,000 | $0 | $0 | $0 | $0 | $3,000 |
Current Penalty | $1,500 | $0 | $0 | $0 | $0 | $1,500 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 2200080101 | 12/15/1992 | 11/20/1995 | $1,500 | $3,000 | $0 | 01/12/1993 | R - Review Commission |
Investigation Summary
AN FMC LINK-BELT TRUCK CRANE WAS BEING USED TO MOVE A LOAD. THE CRANE'S BOOM CONTACTED A 34.5-KILOVOLT OVERHEAD POWER LINE WHILE TWO EMPLOYEES WERE HOLDING ONTO THE LOAD WITH THEIR HANDS. BOTH EMPLOYEES RECEIVED ELECTRIC SHOCKS THAT KNOCKED THEM TO THE GROUND. EMPLOYEE #1 RECEIVED ELECTRICAL BURNS ON HIS LEFT HAND AND RIGHT FOOT AND ON THE RIGHT SIDE OF HIS BACK. AS A RESULT, THE EMPLOYEE LOST THE LITTLE TOE ON HIS RIGHT FOOT. EMPLOYEE #2 RECEIVED ELECTRICAL BURNS ON HIS HANDS AND FEET. BOTH EMPLOYEES WERE HOSPITALIZED FOR THEIR INJURIES.
Keywords: AMPUTATED, ELECTRICAL, E GI IA, ELECTRIC SHOCK, BURN, CRANE BOOM, OVERHEAD POWER LINE, TOE, BOOM, CRANE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 114942147 | Hospitalized injury | Electric Shock | Occupation not reported |