Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1149258.015 - Marali Telecomm Systems Llc, Its Successors And Assigns

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 1149258.015
Report ID: 0352450
Date Opened: 05/16/2016

Site Address:
Marali Telecomm Systems Llc, Its Successors And Assigns
23730 Log House Road
Gaithersburg, MD 20882

Mailing Address:
1422 W. Main Street Suite 205, Lewisville, TX 75067

Union Status: NonUnion

SIC:

NAICS: 238210/Electrical Contractors


Inspection Type: Fat/Cat

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/31/2016

Emphasis: S:Fall

Case Closed: 01/12/2017


Related Activity
Type Activity Nr Safety Health
Accident 1092146
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $3,575 $0 $0 $0 $0 $3,575
Current Penalty $1,400 $0 $0 $0 $0 $1,400
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260502 D15 11/10/2016 11/21/2016 $1,400 $3,575 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 90321.015
Event: 05/16/2016
Employee falls from cell tower and is killed.

At 3:30 p.m. on May 16, 2016, the employee was measuring and documenting newly installed equipment on a cell tower at the 208-foot level. The employee was attached with both "D" rings from his double lanyard to a Remote Radio Head Unit (RRU) Rack. The RRU Rack was attached to the tower by angle adaptors that were not tied into the structure of the tower. The employee, with fall protection attached to the rack, fell backward from the tower. He then fell 208 feet to the ground, along with the Remote Radio Head Unit (RRU) Rack, when the RRU Rack broke free from the tower. The employee fell 208-feet to an HVAC unit, striking the side of a one story building, and was killed.

Keywords: Anchor, Communication Tower, Fall, Fall Protection

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1149258.015 24 M Fatality Occupation Not Listed
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close