Powered by GoogleTranslate

Inspection Detail

Inspection: 114883812 - Kawasaki Robotics

Inspection Information - Office: Miosha General Industry Safety & Health Division

 

Inspection Nr: 114883812
Report ID: 0552652
Date Opened: 03/09/1993

Site Address:
Kawasaki Robotics
24402 Sinocola Court
Farmington Hills, MI 48335

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:8731

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/23/1993

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 07/20/1993


Related Activity
Type Activity Nr Safety Health
Accident 360996516
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 5
Current Violations 3 2 5
Initial Penalty $3,750 $0 $0 $0 $0 $3,750
Current Penalty $2,250 $0 $0 $0 $0 $2,250
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 4081400202 03/31/1993 04/22/1993 $750 $750 $0 -  
2. 01002 Serious 4081400402 03/31/1993 04/22/1993 $750 $750 $0 -  
3. 01003 Other 4081400906 03/31/1993 04/22/1993 $0 $750 $0 A - Amendment  
4. 01004 Serious 4081400403 03/31/1993 04/22/1993 $750 $750 $0 -  
5. 01005 Other 19101200 H 03/31/1993 04/22/1993 $0 $750 $0 A - Amendment  

Investigation Summary

Investigation Nr: 170220784
Event: 03/09/1993
ELECTRIC SHOCK - DIRECT CONTACT WITH ENERGIZED PARTS

AN EMPLOYEE WAS WORKING ON A CONTROL BOX TO INSTALL A SHUNT RESISTOR THAT WAS NEEDED TO PERFORM A TEST. HE CONTACTED AN ENERGIZED PART OF THE CIRCUIT AND RECEIVED AN ELECTRIC SHOCK. OTHER EMPLOYEES HEARD HIM YELL AND FOUND HIM LYING ON THE FLOOR. HE HAD BEEN ELECTROCUTED.

Keywords: E GI IV, ELECTRICAL, ELECTRICIAN, ELECTROCUTED, ELECTRICAL WORK, LOCKOUT, ELEC CIRC PART--MISC, ELECTRICAL BOX

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 114883812 Fatality Electric Shock Electricians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.