Inspection Detail
Inspection: 114632615 - Town Of Lyman
Inspection Information - Office: Wyoming Department Of Workforce Services - Osha Division
Site Address:
Town Of Lyman
Us Highway 30
Lyman, WY 82937
Mailing Address:
P.O. Box 300, Lyman, WY 82937
Union Status: NonUnion
SIC:9199
NAICS: 0
Inspection Type: Unprog Rel
Scope: Complete
Advanced Notice: Y
Ownership: LocalGovt
Safety/Health: Safety
Close Conference: 02/09/1993
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 04/01/1993
Investigation Summary
Employees #1 and #2 were using a propane Weedburner to attempt to thaw-out a frozen water line in a water monitor manhole. The Weedburner was left unattended for several hours. When Employees #1 and #2 returned to the manhole, the Weedburner had lost its flame and the propane from the Weedburner tank had accumulated in the manhole. The employees believed that the weedburner flame had gone out because the propane tank was empty. A week later, Employees #1 and #2 returned to the water monitor manhole to attempt again to thaw out the frozen water line. One employee entered the manhole while the other one handed him the lit Weedburner wand. Employees #1 and #2 were struck by a flash fire, resulting from an accumulation of propane as in the manhole. Both employees received second-degree burns on their faces and hands for which they were hospitalized. Employees #1 and #2 did not perform atmospheric testing of the manhole before entering or using equipment.
Keywords: FLAMMABLE VAPORS, WORK RULES, EXPLOSION, PROPANE, MANHOLE, HAND, BURN, CONFINED SPACE, FIRE, FACE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 114632615 | Occupation Not Listed |