Inspection Detail
Inspection: 114143969 - National Tool & Manufacturing Co.
Inspection Information - Office: Avenel Area Office
Site Address:
National Tool & Manufacturing Co.
1137 Globe Ave.
Mountainside, NJ 07092
Mailing Address:
, , 00000
Union Status: Union
SIC:3544
NAICS: 0
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/25/1997
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 09/03/1997
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 201310737 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 6 | 6 | ||||
Current Violations | 6 | 6 | ||||
Initial Penalty | $22,500 | $0 | $0 | $0 | $0 | $22,500 |
Current Penalty | $11,250 | $0 | $0 | $0 | $0 | $11,250 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100147 C04 I | 08/01/1997 | 08/08/1997 | $1,125 | $2,250 | $0 | I - Informal Settlement | ||
2. | 01002 | Serious | 19100147 C05 I | 08/01/1997 | 08/08/1997 | $2,250 | $4,500 | $0 | I - Informal Settlement | ||
3. | 01003 | Serious | 19100147 C07 I | 08/01/1997 | 08/18/1997 | $1,125 | $2,250 | $0 | I - Informal Settlement | ||
4. | 01004A | Serious | 19100333 A | 08/01/1997 | 08/08/1997 | $2,250 | $4,500 | $0 | I - Informal Settlement | ||
5. | 01004B | Serious | 19100333 B02 I | 08/01/1997 | 08/08/1997 | $0 | $0 | $0 | - | ||
6. | 01005 | Serious | 19100333 C02 | 08/01/1997 | 08/08/1997 | $2,250 | $4,500 | $0 | I - Informal Settlement | ||
7. | 01006 | Serious | 19100335 A01 I | 08/01/1997 | 08/08/1997 | $2,250 | $4,500 | $0 | I - Informal Settlement |
Investigation Summary
A maintenance worker was testing a relay that was not opening. The relay remained energized while he was performing electrical tests. The employee was working on the 120-volt side of the Bliss Press Forging machine where the relay was located. He apparently could not find the problem. The 480-volt generator-inductor located behind the machine had been left uncovered by another employee, and it had not been deenergized. The maintenance employee contacted the unguarded 480-volt circuit parts and received an electric shock. He lost consciousness and was transported to a hospital. He was still at the hospital, unconscious, when the accident summary was completed.
Keywords: REPAIR, E GI IV, ELECTRICAL, ELECTRICAL TESTING, ELECTRICAL WORK, LOCKOUT, ELEC CIRC PART--MISC, ELECTRIC SHOCK
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 114143969 | Hospitalized injury | Electric Shock | Not specified mechanics and repairers |